Dewalt forced air propane construction heater (32 pages)
Summary of Contents for DeWalt DXH210FAVT
Page 1
If you have questions or comments, contact us. 855-805-5745 • www.dewalt.com INSTRUCTION MANUAL Forced Air Propane Construction Heater DXH210FAVT READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, adjust or operate the heater.
Definitions: Safety Guidelines The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CONTENTS WARNING: RISK OF FIRE OR EXPLOSION • Do not store or use gasoline or other flammable vapors and liquids in WARNINGS ................. 2-3 the vicinity of this or any other appliance. HEATER SPECIFICATIONS ............. 3 • WHAT TO DO IF YOU SMELL GAS: OPERATING PRECAUTIONS ..........
Operating Precautions modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater. WARNING When the heater is to be operated in the presence of other people the This is a propane, direct-fired, forced air heater.
15. Use only the electrical power specified. The electrical connection and • Get everyone out of the building and away from the area immediately. grounding must comply with National Electrical Code - ANSI/NFPA 70 (USA) • Close all propane (LP) gas tank or cylinder fuel supply valves, or the main and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
Attention—Critical Points to Remember! STOP Securely close valve on the propane cylinder. • Propane (LP) gas has a distinctive odor. Learn to recognize these odors. Continue to operate heater until all fuel in the hose has burned. (Reference Fuel Gas Odor and Odor Fading sections above. Unplug the heater from electrical supply.
Servicing 3 cylinders 100# (45.4 kg) A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly: • The flame is contained within the heater. • The flame is essentially blue with perhaps some yellow tipping.
210FAVT - WIRING DIAGRAM WARNING When using a thermostat controlled heater, its exit area should be protected from personnel and warnings posted of sudden startup. RECOMMENDED MINIMUM GAUGE FOR CORD EXTENSIONS Wire Gauge Chart A.W.G. Name Plate 120V Cord Length in Feet Amps.
Replacement parts are only available direct from the factory and must be installed by a qualified service agency. PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any DeWalt local ® dealer or direct from the factory...