Item
Condition
4. TX high
1) Set panel test mode
power
CH No. : 1
check
Signalling No. : 1
PTT : ON
2) CH No. : 2
Signalling No. : 1
PTT : ON
3) CH No. : 3
Signalling No. : 1
PTT : ON
5. TX low
1) Set panel test mode
power
CH No. : 3
adjustment
Signalling No. : 1
Select POW
LO
PTT : ON
6. TX low
1) Set panel test mode
power
CH No. : 1
check
Signalling No. : 1
Set low power (Push Side2)
PTT : ON
2) CH No. : 2
Signalling No. : 1
Set low power (Push Side2)
PTT : ON
3) CH No. : 3
Signalling No. : 1
Set low power (Push Side2)
PTT : ON
7. DQT balance 1) Set panel test mode
adjustment
CH No. : 3
Signalling No. : 1
Select BLNC
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Ammeter
Panel
Power meter Panel
ANT
Panel
Deviation
meter
Oscilloscope
AG
Side
Universal
AF VTVM
Adjustment
Parts
Method
Check
3.7W~5.2W
2.3A or less
± 0.1W
Top1/
1.0W
Top2
1.2A or less
Check
0.5W~1.5W
1.2A or less
Top1/
Make the demodu-
Top2
lation waves into
square waves.