Power can not be turned on
Are
voltage
supplied at pins (8)
and (13) of E800 on the PWB
assembly MAIN in standby
mode?
(8): +6.0V
(13): GND
YES
Are voltage
supplied at pins (2),
(3), (5), (6) of E800 on the PWB
assembly MAIN in standby
mode?
(2): +15V
(3): GND(for +15V)
YES
(5): +17V
(6): GND(for +17V)
Does
LAMP (D303) or
TEMP (D302) indicator light
or blink?
NO
Measure
resistance* between
pins (1) and (2) of S801 when
the lamp door is secure.
0
PWB assembly MAIN
CP-A100 / ED-A100 / ED-A110 (A1DN)
*: Be sure to unplug the power cord before measuring resistance.
Measure resistance*
NO
between pins (8) and (13) of
Disconnect TSW
from power unit circuit, and
measure resistance of
Power unit (circuit)
Measure
resistance* between
NO
pins (2) and (3), and between
pins (5) and (6) of
Power unit (circuit)
YES
Go to the next page
Open
Lamp door
Re-attach lamp
door
Re-attach PWB
assembly MAIN
15
0
E800.
Open
Open
TSW.
Short
Fuse on the power unit
0
E800.
Open
PWB assembly MAIN
Power unit (circuit)
Thermal switch (TSW)
(circuit)
PWB assembly MAIN
Power unit (circuit)