Epson Solar Series Watch Movement Specification And Drawing

Epson Solar Series Watch Movement Specification And Drawing

Hide thumbs Also See for Solar Series:

Advertisement

Quick Links

Watch Movement Specification and Drawing
SOLAR SERIES
Cal. VS76A
Movement Size
12'''
Casing Diameter
27.0mm
Ø
Height
4.40mm
Running Time
Approx. 6 months

Advertisement

loading

Summary of Contents for Epson Solar Series

  • Page 1 Watch Movement Specification and Drawing SOLAR SERIES Cal. VS76A Movement Size 12’’’ Casing Diameter 27.0mm Ø Height 4.40mm Running Time Approx. 6 months...
  • Page 2 Date: 24/Sep./'19 Cal. VS76A Items Rev. Page Features Specifications Appearance Casing Hand fitting Hand setting stem Dial Solar cell unit Attention-01 9-01 Attention-02 9-02 Attention-03 9-03 Operation-01 10-01 Operation-02 10-02...
  • Page 3 Date : 24/Apr./'15 Cal. Features VS76A Rev. : 01 1.Solar-powered watch This watch is a solar-powered watch containing a solar cell underneath the dial to convert any form of light into '' electrical energy'' and store the power in a secondary battery. 2.
  • Page 4: Specifications

    Date : 1/Sep./'15 Cal. VS76A Specifications Rev. : 02 Solar Analog Quartz 12''' Center Second Chronograph Movement 1. MOVEMENT DIMENSIONS Outside diameter φ27.60mm(12H-6H) × 24.00mm(3H-9H) Casing diameter φ27.00mm(12H-6H) Total height 4.4mm 2. TIME STANDARD Type of quartz oscillator Tuning fork Frequency of quartz oscillator 32,768 Hz Accuracy...
  • Page 11 Date : 24/Sep./'19 Cal. Attention-01 VS76A Rev. : 02 1. Attention for solar cell unit Pay attention not to touch and scratch the surface of the solar cell. 2. Dial transparency rate Keep the transparency rate of the dial more than 30%. (Effective aperture is φ27mm) Each elements of solar cell must be kept the transparency rate.
  • Page 12 24/Sep./'19 Date : Cal. Attention-02 VS76A Rev. : 02 6. How to remove the setting stem ・ When removing the setting stem, pull out the crown at 1st click position and then remove the setting stem while pressing the hollow portion of setting lever by tweezers. (Refer to the Fig.[3].) ・...
  • Page 13 24/Sep./'19 Date : Cal. Attention-03 VS76A Rev. : 01 13.How to set the dial The dial is held by the four guide poles on the solar cell unit. 14.System reset as complete watch System-reset(Refer to Operation-01[*1].) is required in case of below, ― after replacement of secondary battery unit.
  • Page 14 Date : 24/Apr./'15 Cal. VS76A Operation-01 Rev. : 01 Second chronograph hand 1/20 second chronograph hand Hour hand Minute hand 2H button Small second hand 0 ® 1 ® 2 Crown 4H button Minute chronograph hand Crown position 0 click 1st click 2nd click Turn clockwise for date...
  • Page 15 Date : 24/Apr./'15 Cal. VS76A Operation-02 Rev. : 01 Chronograph function ・ The chronograph can measure up to 60 minutes in 1/20 second increments. ・ After the chronograph is started or restarted or split time is released, 1/20 second chronograph hand moves about 1 minute and automatically stops at the "0"...