Download Print this page
Sealey VS402.V3 Instructions Manual

Sealey VS402.V3 Instructions Manual

Vacuum tester and brake bleeding kit

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
1. SAFETY
Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
Use approved parts only. Unapproved parts will invalidate the warranty.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
Ensure the work area has adequate lighting.
9
DO NOT use the kit to perform a task for which it is not designed.
8
DO NOT hold pump inlet against the skin whilst using the pump.
8
DO NOT allow untrained persons to use the kit.
8
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
8
After use, clean equipment and store in a cool, dry, childproof area.
9
WARNING! Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
WARNING! Brake fluid is flammable - keep away from sources of ignition, including hot surfaces e.g. exhaust manifold.
Dispose of waste liquids in accordance with local authority regulations.
9
WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Always read and comply with the warnings on the brake fluid container.
9
Wear eye protection and keep skin contact to a minimum. If brake fluid enters eyes rinse with plenty of water and seek medical advice. If
9
swallowed seek medical advice immediately.
2. INTRODUCTION
The VS402 vacuum tester and brake bleeding kit is a multi-function diagnostic tool used to test a variety of essential engine and associated
functions including fuel, ignition, transmission and emissions. Set also includes reservoir, hoses and adaptors for bleeding brake and clutch systems
on cars, commercials and motorcycles. Brass-bodied vacuum pump features large, easy-to-read vacuum gauge calibrated in both inches and
millimetres of mercury.
3. CONTENTS
ITEM
PART No.
1
VS402.V3-01
2A
VS402.V3-02A
RESERVOIR LID (FOR OPERATION)
2B
VS402.V3-02B
RESERVOIR LID (FOR TRANSPORT)
3
VS402.V3-03
4
VS402.V3-04
5
VS402.V3-05
© Jack Sealey Limited
INSTRUCTIONS FOR:
VACUUM TESTER AND BRAKE BLEEDING KIT
MODEL No.
Wear eye
protection
DESCRIPTION
VACUUM PUMP WITH GAUGE
RESERVOIR JAR
560mm VACUUM HOSE
80mm VACUUM HOSE
Original Language Version
VS402.V3
ITEM
PART No.
6
VS402.V3-06
7
VS402.V3-07
8
VS402.V3-08
9
VS402.V3-09
10
VS402.V3-10
DESCRIPTION
HOSE ADAPTOR
HOSE ADAPTOR 'T-PIECE'
HOSE ADAPTOR 'STRAIGHT'
BRAKE BLEED NIPPLE ADAPTOR
UNIVERSAL CUP ADAPTOR
VS402.V3 | Issue - 1 14/09/16

Advertisement

loading

Summary of Contents for Sealey VS402.V3

  • Page 1 VS402.V3 MODEL No. Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Operation

    CAUSE: Over lean or rich mixture. CAUSE: Blown cylinder head gasket manufacturer’s specification. Check and reset in accordance with between two adjacent cylinders. Carry manufacturer’s specifications. out cylinder leakage test. Original Language Version VS402.V3 | Issue - 1 14/09/16 © Jack Sealey Limited...
  • Page 3: Fuel Systems

    6.3.2. To test the fuel rail pressure, a gauge is attached to the rail, then engine loads must be created to vary engine manifold vacuum. Simply Original Language Version VS402.V3 | Issue - 1 14/09/16 © Jack Sealey Limited...
  • Page 4 VS402 vacuum tester (fig.12). Start and run the engine and apply vacuum pressures. Monitor readings and confirm that these are in conformance with manufacturer specifications. Original Language Version VS402.V3 | Issue - 1 14/09/16 © Jack Sealey Limited...
  • Page 5: Braking Systems

    Remove the cap of the vehicle’s master brake fluid reservoir. If the fluid level is not at maximum, top it up. 8.3.3. Attach the appropriate size bleeding attachment to the bleed nipple on the brake calliper of the first wheel, normally nearest to master brake fluid reservoir. Original Language Version VS402.V3 | Issue - 1 14/09/16 © Jack Sealey Limited...
  • Page 6 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. Sole UK Distributor, Sealey Group. 01284 757500 www.sealey.co.uk Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk. 01284 703534 sales@sealey.co.uk IP32 7AR Original Language Version VS402.V3 | Issue - 1 14/09/16 © Jack Sealey Limited...

This manual is also suitable for:

Vs402.v3-01Vs402.v3-02aVs402.v3-02bVs402.v3-03Vs402.v3-04Vs402.v3-05