NOTE
• Fully make sure that the front cover has been reinstalled securely. Always tighten the installation screws of the front cover.
 Removal of the wiring cover
• FR-E860-2.2K(0040) or lower
(a)
Screwdriver
Screwdriver
Screwdriver
(a)
Insert a tool such as a flathead screwdriver into the half-hole above the "PUSH" mark on the wiring cover to push the stopper behind the
wiring cover approx. 3 mm.
(b)
Pull out the cover along the guides in the direction shown by the arrow in the figure above.
• FR-E860-3.7K(0061) or higher
(a)
Screwdriver
Screwdriver
Screwdriver
(a)
Insert a tool such as a flathead screwdriver into the half-hole above the "PUSH" mark on the wiring cover to push the stopper behind the
wiring cover approx. 3 mm.
(b)
Pull out the cover along the guides in the direction shown by the arrow in the figure above.
 Reinstallation of the wiring cover
• FR-E860-2.2K(0040) or lower
Fit the cover to the inverter along the guides, and push the hook into the socket.
• FR-E860-3.7K(0061) or higher
Fit the cover to the inverter along the guides.
Hook
Hook
(b)
(b)
Guides
Guides
Guides
Guides
Guides
Guides
2.2 Removal and reinstallation of the front cover