Operating Instructions: 
Touch screen control has been used for all functions. 
1.
When plug in, the Bi Bi sound alerts, then the fan will enter into standby mode.
2.
Press the function buttons on the Touch‐control panel as below:
POWER: Turn the fan on by pressing the "On/Off" button, the fan enters to Normal mode.
Press again to turn it off and the fan enters into Standby mode. Unplug the power cord to 
turn off the fan completely. 
Remark: It is recommended to unplug the power when not using the machine to prolong its
lifetime. 
SPEED: Press the "Speed" button to adjust the fan speed to a desired level: Hi, Mid, Low.
The LED indicator will change accordingly, Hi (         ), Mid (        ), Low (      ). 
Remark: When low speed is selected, the motor will start at mid fan speed for few seconds
and then operate at low speed.
MODE: Press "Mode" button to change the fan mode: Normal, Natural, Sleep, 6
Air‐condition mate mode. The LED indicator will change accordingly, Natural (           ), Sleep 
th
6
 sense (       ), 
(        ), 
Natural Mode: Fan speed will fluctuate automatically in a set time interval to simulate 
natural wind. Under natural mode operation,  3 fan speeds are available for options. 
Sleep Mode: Fan speed will fluctuate automatically in a set time interval to provide a
comfort sleeping environment. Under sleep mode operation,  3 fan speeds are available for 
options. 
th
6
 Sense Mode: The fan speed will change automatically according to the room temperature.
When the room temperature is lower than 25°C, the fan speed runs at Low level. When the 
room temperature is higher than 29°C, the fan speed runs at Hi level. When the room 
temperature is between 25°C to 29°C, the fan speed will run at Mid level.
Air‐condition mate Mode: Fan speed will fluctuate automatically in a set time interval and
helps to circulate the cold air in the room when together works with the Air Conditioner.
Remark: Under 6th Sense mode and Air‐condition mate mode, the fan speed LED indicator 
will not show in the panel display because "Speed" button does not work.
TIMER: Press "Timer" button to set 1H, 2H, 4H, 8H timer setting. If the timer set to 0 hour, 
timer function off. The LED display will show the time being pressed. The fan will 
automatically shut off when the timer is over. 
SWING: Press "Swing" button to turn on the oscillation function. Press again to cancel.
Manual Louver: Adjust the vertical louver manually for upward and downward airflow.
3.
LED display shows the current room temperature. LED display light can be dimmed after
1 minute without any control. 
4.
Under standby mode, all functions have memory except timer and sleep mode.
Air‐condition mate (           ). 
th
 sense and

Advertisement

Table of Contents
loading

Table of Contents