Grounding; Test Run - Toshiba RAS-2M10U2AVG-E Installation Manual

Hide thumbs Also See for RAS-2M10U2AVG-E:
Table of Contents

Advertisement

Outdoor Unit
CAUTION
• Incorrect/incomplete wiring will cause
electrical fi res or smoke.
• Prepare the power source for exclusive
use with the air conditioner.
• This product can be connected to the
main power.
Fixed wire connections:
A switch that disconnects all poles and
has a contact separation of at least
3 mm must be incorporated into the fi xed
wiring.
Wire Connection
• The dash lines show on-site wiring.
(Main circuit)
Input power
L
N
Leakage
breaker
Earth
• Connect the indoor/outdoor connecting cables to the identical terminal
numbers on the terminal block of each unit.
• Incorrect connection may cause a failure.
Model
RAS-2M10U2AVG-E
Power supply
Maximum running
12.3A
current
Installation fuse
rating
Power cord
Connecting cable
1. Remove the valve cover screws.
2. Pull the valve cover in the direction of arrow, and remove it.
3. Remove the cord clamp and the terminal cover.
(System
interconnection wires)
1
1
2
2
Remote
3
3
controller
Indoor unit
RAS-2M14U2AVG-E
RAS-3M18U2AVG-E
RAS-2M18U2AVG-E
1ph, 50Hz, 220-240V
12.6A
13.1A
15A
(All types can be used)
H07RN-F or 60245 IEC 66
3-core 1.5 mm²
H07RN-F or 60245 IEC 66
4-core 1.0 mm²
Valve cover
Terminal cover
Cord clamp
4. Connect the wires for the power source and each indoor unit.
• Connect the connecting cable to the terminal as identifi ed by the
matching numbers on the terminal block of the indoor and the outdoor
unit.
5. Fix the wiring connections for the power source and each indoor unit
securely using a cord clamp.
6. Attach the terminal cover and the valve cover.
Stripping Length of connecting cable for outdoor unit
1 2 3
5
55
Earth wire
Connecting cable
Earth screw
Connecting cable
Unit A
Earth screw
Connecting cable
Unit B
8

Grounding

This air conditioner must be grounded without fail.
• Grounding is necessary not only to safeguard against the possibility
of receiving an electric shock but also to absorb both static, which is
generated by high frequencies and held in the surface of the outdoor unit,
and noise since the air conditioner incorporates a frequency conversion
device (called an inverter) in the outdoor unit.
• If the air conditioner is not grounded, users may receive an electric shock
if they touch the surface of the outdoor unit and that unit is charged with
static.
9

Test run

Wiring/Piping Check
CAUTION
Electric current is applied on the
control board. Beware of electric
shock.
1. Remove the valve cover screws.
2. Pull the valve cover in the direction of arrow, and remove it.
12
Installation Manual
L N
5
5
30
30
Power cord
Earth screw
Power cord
Earth screw
Connecting cable
Unit C
Valve cover
LED
Service switches
D801
D803
D805
SW02
D800
D802
D804
SW01
5
55
Earth wire
EN
FR
DE
IT
ES
PT
GR
PL
CZ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents