Download Print this page

DeWalt DWH205 Manual page 8

Hide thumbs Also See for DWH205:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH
source before making any adjustments or removing/
installing attachments or accessories. Be sure the
trigger switch is in the OFF position. An accidental start-up
can cause injury.
Your dust collector has been designed to operate over a long
period of time with a minimum of maintenance. Continuous
satisfactory operation depends on proper tool care and regular
cleaning. Empty the dust extractor periodically or when the
performance has noticeably decreased.
Replacing the Dust Collection Box Filter
Assembly (Fig. F)

WARNING: Wear approved eye protection and approved
dust mask when performing this procedure.
NOTE: The filter should be replaced after every 350 cycles
of use.
1. Press the dust collection box release buttons 
dust collection box away from the dust extraction system.
Once the catch mechanism is clear of the dust extraction
system the upper joint will also release allowing the dust
collection box to be removed completely.
2. Discard dust collection box
DWH302DH filter box.
3. Reattach the dust collection box to the dust extraction
system. First insert the rounded profile of the upper joint
into the recess on the dust extraction system. Pivot the dust
collection box down so that the release buttons click back
into place.
Attaching and Removing Small, Standard and
Stop Bit Heads (Fig. H)

WARNING: Wear approved eye protection and approved
dust mask when performing this procedure.
The dust brush
11
will wear during use and will need to be
replaced at the same time as the filter.
Insert the dust extraction head
thelescope as shown in FIgure H. The head will snap
into place.
To remove a dust extraction head from the unit, press and
hold the release button
out to remove.
Lubrication
Your dust extractor requires no additional lubrication.
Cleaning

WARNING: Wear approved eye protection and approved
dust mask when performing this procedure.

WARNING: Do not use a brush to clean the dust collector
or filter.

WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
6
and pull the
 2 
replace with a new
1
10
inot the end of
17
. Pull the dust extraction head
chemicals may weaken the plastic materials used in
these parts. Use a cloth dampened only with water and
mild soap. Never let any liquid get inside the tool; never
immerse any part of the tool into a liquid.
During intensive use the dust collector becomes clogged
with dust. Refer to Replacing The Dust Collector Box Filter
Assembly, under Maintenance.
Optional Accessories

WARNING: Since accessories, other than those offered
by D
WALT, have not been tested with this product, use
e
of such accessories with this tool could be hazardous.
To reduce the risk of injury, only D
accessories should be used with this product.
Consult your dealer for further information on the
appropriate accessories.
Protecting the Environment
Separate collection. Products and batteries marked
with this symbol must not be disposed of with normal
household waste.
Products and batteries contain materials that can
be recovered or recycled reducing the demand for raw
materials. Please recycle electrical products and batteries
according to local provisions. Further information is available at
www.2helpU.com.
WALT recommended
e

Advertisement

loading