Self-Diagnosis Code Table - Sony HXR-NX80 Service Manual

Solid-state memory camcorder
Hide thumbs Also See for HXR-NX80:
Table of Contents

Advertisement

2-1-3.

Self-diagnosis Code Table

Self-diagnosis Code
Block
Detailed
Function
Code
C
0 4
0 0
C
0 6
0 0
C
0 6
0 1
C
1 3
0 1
C
1 3
0 2
C
1 3
0 3
C
1 3
0 4
C
3 2
0 1
C
3 2
6 0
E
2 0
0 0
E
3 1
0 0
E
4 1
0 0
E
4 1
0 1
E
4 1
*2
1 0
E
6 1
0 0
E
6 1
1 0
E
6 1
1 1
*1:
Start the Adjust Manual in the Adjust Station and execute the "Destination data write" on the ADJUST tab.
*2:
Function of this code is not provided in this unit.
HXR-NX80/HXR-MC88
Symptom/State
Non-standard battery is used.
The battery pack temperature is
high.
The unit temperature is high.
Memory card is unformatted or
memory card is broken.
Access error
Access error (External media)
Abnormality of the drive (External
media)
Trouble with hardware
Difficult to adjust focus
(Cannot initialize focus)
Flash memory data are rewritten.
Abnormality of the drive
Abnormality of the wireless LAN
module or CPU
Abnormality of network control de-
vice
Wired Ethernet device error
Difficult to adjust focus
(Cannot initialize focus)
Zoom operations fault
(Cannot initialize zoom lens)
Focus or zoom fault
Correction
Use the InfoLITHIUM battery.
Change the battery pack or place it in a cool place.
Place this unit in a cool place.
Format the memory card.
Insert a new memory card.
Remove the power source. Reconnect it again and operate
the unit again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again.
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Make flash memory data correct value.
Turn power off and turn power on again.
The peripheral circuit of between CPU and wireless LAN
module may be faulty.
Replace the board that contains this peripheral circuit.
Turn power off and turn power on again.
The peripheral circuit of between Wired Ethernet device
may be faulty.
Replace the board that contains this peripheral circuit.
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Turn power off and turn power on again. When this error is
not cleared, operate the zoom lever and check following
items.
When zooming is performed, the zoom control signal
for the lens block may be faulty.
When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis
code.
*1
Continued
2-2