TROUBLESHOOTING

3.16.5 OTHER TROUBLES

(•): Always contact your Komatsu Utility Dealer when you have to carry out this operation.
• : If the anomaly or its cause are not included in the failures indicated below, contact your Komatsu Utility Deal-
er for the necessary repair.

3.16.5.1 ELECTRICAL CIRCUIT

TROUBLE
Lights do not work satisfactorily even
with engine running at high speed:
Lights come on intermittently with
engine running:
Alternator charge warning light does
not go out with engine running and
increasing speed:
Alternator emits an abnormal noise:
Starter does not turn with key in
START position:
Starter pinion engages and then dis-
engages:
Starter makes engine run slowly:
Starter disengages before engine has
started:
Engine oil pressure warning light does
not come on when engine is stopped
(ignition key in position « »):
Alternator charge warning light does
not come on when engine is stopped
(ignition key in position « »):

3.16.5.2 HYDRAULIC SYSTEM

TROUBLE
Pump emits an abnormal noise:
Equipment control levers do not return
automatically to neutral position:
Equipment moves only at low speed:
116
CAUSE
Faulty cables.
Faulty fan belt tension.
Faulty alternator.
Faulty cables.
Faulty alternator.
Faulty cables.
Battery charge insufficient.
Faulty main fuse.
Battery charge insufficient.
Battery charge insufficient.
Faulty starter.
Faulty cables.
Battery charge insufficient.
Faulty bulb.
Faulty pressure sensor.
Faulty bulb.
Faulty cables.
CAUSE
No oil in the tank.
Faulty pump.
Hydraulic oil unsuitable for the tem-
perature.
Broken return spring or seized ele-
ment.
Faulty pump.
Max. pressure valve setting incor-
rect, or valves not closed due to im-
purities.
Dirty drain filter.
REMEDY
(•)
Check and repair any loose termi-
nal and connection.
Adjust fan tension (see "EVERY 250
HOURS").
(•)
Change.
(•)
Check and repair.
(•)
Change.
(•)
Check and repair.
Charge battery.
Change.
Charge battery.
Charge battery.
(•)
Change.
(•)
Check and repair.
Charge battery.
(•)
Change.
(•)
Change.
(•)
Change.
(•)
Check and repair.
REMEDY
Top up.
(•)
Repair or change.
Change.
(•)
Change spring or distributor ele-
ment.
(•)
Repair or change.
(•)
Set or change.
Change.