Contact-Type Digital Displacement Sensor / Sensor Head Air-Driven Type
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
W A R N I N G
Never use this product as a device for personnel protection.
When using devices for personnel protection, use products that meet the laws
and standards for personnel protection that apply in each region or country, such
as OSHA, ANSI and IEC.
This document provides a brief summary of mounting and other related information.
For detailed information, refer "our web site (https://panasonic.net/id/pidsx/global) "
1
STANDARDS AND REGULATIONS
This product conforms to the standards and regulations below.
<European Directives>
EMC Directive
2
CONTENTS OF PACKAGE
Sensor head
Mounting nut
Sensor head fastening wrench
Air tube clamp
Instruction Manual (English / Japanese, Chinese / Korean)
General Information for Safety, Compliance, and Instructions(23 languages) 1 pc.
3
DESCRIPTION OF PARTS
Sensor head connection
cable connector
Operation indicator
(Orange / Green)
Note: The seal cap is provided as a maintenance part. HG-SASCX5 (5 pcs. per set)
4
MOUNTING
Mounting on the housing
to the thickness of the housing.
1. Open a hole in the housing in which the
sensor head will be mounted
2. Insert the sensor head into the hole you opened in the
housing, and fasten lightly with the provided mounting nut.
Mounting nut with the
thread facing down
A
Housing
Housing
Thread
Thickness of the housing
A
HG-S1010-AC, HG-S1110-AC
6.5 to 10mm
Note: Please use within a the thickness of the housing range of 6.5~12.5mm.
INSTRUCTION MANUAL
MJE-HGSAC No.0074-51V
When air is supplied
Air tube joint
Mounting nut
Seal cap (Note)
Probe
Thickness of
Mounting hole
the housing
8H7
Mounting nut with the
thread facing up
B
Thread
B
10 to 12.5mm
3. Fasten the sensor head.
Tighten the mounting nut with a wrench
while holding the sensor head in place
with the sensor head fastening wrench as
shown.Tighten to a torque of 12.5N·m or
less.
Connecting the sensor head connection cable
When disconnecting, always make sure that the fastening ring has been com-
pletely loosened before pulling out the cable.Risk of damage if you pull the cable
with excessive force (15N or more) with the fastening ring tightened.
Sensor head connection cables with an L-shaped connector cannot be used.
How to connect
1. Insert the sensor head connection
cable into the connector for the
sensor head connection cable on
the sensor head.
2. Turn the fastening ring on the sen-
sor head cable in the direction
1 pc.
1 pc.
1 pc.
How to remove
1 pc.
1. Turn the fastening ring on the sen-
1 pc. each
sor head cable in the direction
shown to loosen the ring.
2. Grasp each connector on the sen-
sor head connection cable and pull
out to remove.
Connecting the air tube
the air tube is used without inserting or securing it properly, there is a danger that
How to connect
1. While loosening the air tube clamp, slide it from the tip of the air tube and then
release it when it reaches halfway through the tube.
2. Insert the tip of the air tube until it reaches the root of the joint on the sensor
head.
3. Move the air tube clamp and secure the tip of the air tube.
4-mm-diameter air tube
Spindle
How to disconnect
1. While loosening the air tube clamp, move it halfway
through the air tube.
2. Grasp the sensor head and pull out the air tube.
Note: Take care not to lose the air tube clamp.
5
AIR CIRCUIT (RECOMMENDED)
if necessary, adjust the speed of the spindle with the speed control valve.
Air pressure source
+0.015
mm
0
Notes: 1) Supply clean air (free from moisture, oil, dust, or other foreign objects) to this product.
2) Air pressure may decrease, depending on the length of the air pipe from the air supply source or any pneu-
Mounting nut
plied air pressure.
(Accessory)
3) The 3-port solenoid valve and speed control valve have their respective mounting directions. Mount each
valve in their correct direction by referring to the above diagram.
4)
recommended.
1. Insert
1. Loosen
Air tube clamp
(Accessory)
3-port solenoid valve
Precision regulator
Filter + Mist separator + Regulator
Sensor head
fastening wrench
(Accessory)
Mounting nut
(Accessory)
-
2. Tighten
fastening ring
2. Pull out
Speed control valve
-
-
m or less are

Advertisement

loading

Summary of Contents for Panasonic HG-S -AC Series

  • Page 1 MJE-HGSAC No.0074-51V Sensor head fastening wrench Thank you very much for purchasing Panasonic products. Read this Instruction Man- (Accessory) ual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
  • Page 2 Ensure that the product does not come into contact with organic solvents such as https://panasonic.net/id/pidsx/global thinner. Please visit our website for inquiries and about our sales network. Ensure that the product does not come into contact with strong acid or alkaline. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2020...

This manual is also suitable for:

Hg-s1010-acHg-s1110-ac