Sharp FACSIMILE XU-107 Service Manual page 50

Table of Contents

Advertisement

UX-177H
9
Wire treatment
a. Perform wire treatment carefully and deliberately.
b. For wire treatment procedures which are not described in this
section, refer to the section for that portion of the unit.
THE HEAD CABLE WILL BE PASSED
TO THE CORE AT 3 TIMES.
2
DON'T OVER THIS
LINE BY CABLE.
(KEEP TO ARROW SIDE)
THE SCANNER CABLES WILL BE
PASSED TO THE CORE 2 TIMES.
2
POSITION OF
CORE
1
2
2
IT WILL BE HOOKED THE CABLES BETWEEN
THE HOOKING RIBS.
1
DON'T ON THIS
CORE TO PWB
1
2
1
A
IT WILL BE PASSED THE
CABLE BEHIND THE DRIVE
UNIT AS ARROW A DIRECTION.
Fig. 9
3 – 14
Parts list (Fig. 9)
No.
Part name
1
Band
2
Core
2
2
THE DRIVE UNIT CABLES WILL
BE PASSED TO THE CORE AT 2 TIMES.
2
1
1
FIX THE CORE
LIKE A PICTURE
Q'ty
2
3
2
rib