Installation Method - Whirlpool HB124 Operation Manual

Bathroom ventilation heater
Table of Contents

Advertisement

【Installation Method 】
A. Ceiling fixed frame method
●Installation reference picture:
Install the Fixed Frame to the ceiling.
1)
■Make the fixed frame.
■Please use materials that can bear 6kg to fix the surrounding part.
■The Fixed Frame should use sticks of 30*25mm .
■Size of the inner part of the Frame :375*262mm.
■If there is no exhaust pipe connected to the outdoors, please firstly install hard
exhaust pipe of inner diameter 98.4mm.
) Install the Air outlet joint
2
■Please use three Self-tapping screws(Φ4*25mm) to fix the Air outlet joint in the ceiling of the fixed box.
The Air outlet joint
three Self-tapping screws(Φ4*25mm)
3) Install the Main Body
■Please put the Main Body directly face the guide slot of the Air outlet joint ,then
push up the Main Body.
■Please ensure that the Main Body joined to the Air outlet joint , then use four
subsidiary of the tapping screws (diameter 4 * 25 mm) to fix the MainBody.
4) The minimum distance between the surrounding structures should be 50 cm.
Air outlet joint
Exhaust pipe
Downdip 1-2
Inspecttion opening
Self-tapping screw(4 pieces)
-05-
Over 5cm
Main body
Over 50cm to the wall
Front panel
Sc
Screw hole 2,4,7,9 for
Screw hole 3
,
375mm
Fixed Frame
262mm