Komatsu PC200LC-8 Shop Manual page 8

Hydraulic excavator
Hide thumbs Also See for PC200LC-8:
Table of Contents

Advertisement

FOREWORD
12
PUSH PULL COUPLER
WARNING! Before carrying out the following work,
release the residual pressure from the
hydraulic tank. For details, see TESTING
AND ADJUSTING, Releasing residual pres-
sure from hydraulic tank.
WARNING! Even if the residual pressure is released from
the hydraulic tank, some hydraulic oil flows
out when the hose is disconnected. Accord-
ingly, prepare an oil receiving container.
Type 1
Disconnection
1.
Release the residual pressure from the hydraulic tank. For details,
see TESTING AND ADJUSTING, Releasing residual pressure from
hydraulic tank.
2.
Hold the adapter (1) and push the hose joint (2) into the mating
adapter (3). The adapter can be pushed in about 3.5 mm. Do not hold
the rubber cap portion (4).
3.
After the hose joint (2) is pushed into the adapter (3), press the
rubber cap portion (4) against the adapter until it clicks.
4.
Hold the hose adapter (1) or hose (5) and pull it out. Since some
hydraulic oil flows out, prepare an oil receiving container.
Connection
1.
Hold the hose adapter (1) or hose (5) and insert it in the mating
adapter (3), aligning them with each other. Do not hold the rubber
cap portion (4).
2.
After inserting the hose in the mating adapter, pull it back to check
its connecting condition. When the hose is pulled back, the rubber
cap portion moves toward the hose about 3.5 mm. This does not
indicate an abnormality.
00-8