Auxiliary controls on your Zoneline.
Auxiliary Controls—Terminal Connections
The auxiliary controls are located behind the
room cabinet beneath the access cover.
Remove the room cabinet. See the
1
To Remove the Room Cabinet section.
Remove the screw from the access cover.
2
To make wiring connections, insert the wires
3
into the bottom of the terminals and tighten
screws securely.
After all desired connections have been
4
made, replace the access cover and room
cabinet.
External Fan
Central Desk Control
8
The owner is responsible for making all
connections and setting the appropriate
dip switches.
CAUTION:
Improper wiring may damage the Zoneline
electronics. No common busing is permitted.
Damage or erratic operation may result.
A separate wire pair must be run from each
separate controlling switch to each individual
Zoneline.
Common - Ground
White - Heater
Yellow - Compressor
Black - Solenoid
Green - High Speed Fan
Green - Low Speed Fan
Red - 24 V AC only