STOPPING THE GENERATOR

(1) Turn off the power switch of the elec-
tric equipment.
(2) Turn the economy switch and AC
switch (no-fuse breaker) to off.
(3) Unplug the cord from receptacle of the
generator.
(4) Allow the engine to run at no-load for
about 3 minutes to cool down before
stopping.
(5) Turn the starter switch to the STOP
position.
(6) Close the fuel cock.
TIP
It is normal that the engine speed goes up
for a moment when you turn the starter
switch to "STOP" while the Economy
switch is in the "ON" position.