Replacing The User Program - GE AquaTrans AT868 User Manual

Ultrasonic flow transmitter for water (1- & 2-channel)
Hide thumbs Also See for AquaTrans AT868:
Table of Contents

Advertisement

September 2004
Replacing the User
Program
Accessing the EPROM
7-4
The Model AT868's User Program is stored on an erasable
programmable read-only memory (EPROM) chip. The EPROM,
which is designated as component U4, is mounted in a socket on the
rear of the Channel 1 board. EPROM replacement may be required to
replace a defective chip or to upgrade to a newer software version.
To replace the User Program, refer to Figure 7-1 on page 7-7 and
Figure 7-2 on page 7-8 and complete the following steps:
1. Disconnect the power to the AT868 and move the electronics
enclosure to a flat service.
The main power to the Model AT868 must be disconnected
2. Loosen the six set screws on the front cover. Remove the front
cover.
3. Remove the plastic shroud by removing the two screws that hold it
in place.
4. Remove the four mounting screws on the LCD/keypad board.
Make sure you remove the flat and lock washers with the screws.
5. Grasp the LCD/keypad board by the side edges and carefully pull
it straight upward until it comes free from the Channel 1 board
below it.
6. Disconnect the keypad ribbon on the board below by sliding the
tabs on the connector upward and pulling the ribbon cable out.
7. Remove the four standoffs in the corners of the Channel 1 board.
8. Remove the screw in the middle of the Channel 1 board.
9. Carefully remove the Channel 1 board from the connectors on the
Channel 2 board below it.
!WARNING!
before proceeding.
Parts Replacement

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents