Figure 3-4 Board Configuration Of The Bbu3900; Figure 3-5 Position Of The Cable Trough - Huawei 3900 Series Solution Manual

Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

3 Hardware Description

Figure 3-4 Board configuration of the BBU3900

Configuration Principles of the RF Modules
Configuration principles of the RF modules are as follows:
l
l
Cabling Principles
The routing principles for the RF jumpers are as follows:
l
l
3-10
If the total number of RF modules is not more than six, configure all the RF modules in
one cabinet. If the total number of RF modules is more than six and WRFUs are required,
configure all the WRFUs in the extension cabinet and the DRFUs in the main cabinet. Note
that the BBU is configured in the main cabinet rather than the extension cabinet.
In each cabinet, the DRFUs and WRFUs are alternately installed. For example, if three
DRFUs and three WRFUs need to be installed in a cabinet, the DRFUs are installed in slots
0, 2, and 4 and the WRFUs are installed in slots 1, 3, and 5. If only three RF modules
working in the same standard are configured in the extension cabinet, they should be
configured in slots 0, 2, and 4 respectively.
The RF jumpers are routed inside the cable trough.
cable trough.

Figure 3-5 Position of the cable trough

NOTE
The power cables and signal cables are routed outside the cable trough.
In a single cabinet or two cabinets installed side by side, the RF jumpers are routed inside
the cable troughs to the top of the cabinet by default before they are led out of the cabinet
from two sides.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3900 Series Base Station GU Co-Cabinet
Figure 3-5
shows the position of the
Issue 04 (2009-07-30)
Solution Guide