6.
Flushing operations
After disassembling and assembling the equipment, or changing
the oil, use flushing oil to remove the contaminants, sludge, and
old oil from the hydraulic circuit. Normally, flushing is
performed twice: primary flushing is performed with flushing
oil, and secondary flushing is performed with the specified
hydraulic oil.
7.
Cleaning operations
After repairing the hydraulic equipment (pump, control valve,
etc.), or when running the machine, perform oil cleaning to
remove the sludge or contaminants in the hydraulic oil circuit.
The oil cleaning equipment is used to remove the ultra fine
(about 3
(10 ft)) particles that the filter built in the hydraulic
m
equipment cannot remove, so it is an extremely effective device.
00-16