System Set Up; Dip Switch Functions - Mitsubishi Electric Ecodan EHSC-VM6D-CN Installation Manual

Hydrobox
Hide thumbs Also See for Ecodan EHSC-VM6D-CN:
Table of Contents

Advertisement

5

System Set Up

5.1 DIP Switch Functions

The DIP switch number is printed on the circuit board next to the relevant switch-
es. The word ON is printed on the circuit board and on the DIP switch block itself.
To move the switch you will need to use a pin or the corner of a thin metal ruler or
similar.
DIP switch settings are listed below in Table 5.1.1.
Only an authorised installer can change DIP switch setting under one's own re-
sponsibility according to the installation condition.
Make sure to turn off both indoor unit and outdoor unit power supplies before
changing the switch settings.
DIP switch
Function
SW1 SW1-1
SW1-2
SW1-3
SW1-4
SW1-5 Booster heater
SW1-6
SW1-7 Outdoor unit type
SW1-8
SW2 SW2-1 Room thermostat1 input (IN1) logic change
SW2-2
SW2-3 Booster heater capacity restriction
SW2-4
Automatic switch to backup heat source operation
SW2-5
(When outdoor unit stops by error)
SW2-6
SW2-7
SW2-8 Flow sensor
SW3 SW3-1
SW3-2
SW3-3
SW3-4 Electric energy meter
SW3-5
SW3-6
SW3-7
SW3-8 Heat meter
SW4 SW4-1
SW4-2
SW4-3
SW4-4 Indoor unit only operation (during installation work) *3
SW4-5 Emergency mode (Heater only operation)
SW4-6
SW5 SW5-1
SW5-2 Advanced auto adaptation
SW5-3
SW5-4
SW5-5
SW5-6
SW5-7
SW5-8
SW6 SW6-1
SW6-2
SW6-3
SW6-4 Analog output
SW6-5
Note:
*1 The switch must be turned OFF when the maximum output of heater (5.5 kW) is necessary.
*2. OUT11 will be available. For safety reasons, this function is not available for certain errors. (In that case, system operation must be stopped and only
the water circulation pump keeps running.)
*3. Space heating can be operated only in indoor unit, like an electric heater. (Refer to "5.3 Indoor unit only operation". )
*4. If emergency mode is no longer required, return the switch to OFF position.
WITHOUT Booster heater
Split type
Operation stop at thermostat short
Inactive
Inactive
WITHOUT Flow sensor
WITHOUT Electric energy meter
WITHOUT Heat meter
Inactive
Normal
Inactive
SW5-3
EHSC-VM6D-CN
ON
Inactive
OFF
WITH Booster heater
Packaged type
Operation stop at thermostat open
Active
Active *2
WITH Flow sensor
WITH Electric energy meter
WITH Heat meter
Active
Emergency mode (Heater only operation) OFF *4
Active
Capacity code
SW5-4
SW5-5
SW5-6
SW5-7
ON
ON
ON
OFF
Active
<Table 5.1.1>
<Figure 5.1.1>
ON
Default settings
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON *1
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
SW5
SW4
SW3
SW2
SW1
SW6
en
12