Parameter Name
Maintenance timer 3
689
warning output set
time
Deceleration check
690
time
Second free thermal
692
reduction frequency 1
Second free thermal
693
reduction ratio 1
Second free thermal
694
reduction frequency 2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
707
Motor inertia (integer)
Motor inertia
724
(exponent)
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
Second PID action
753
selection
Second PID control
754
automatic switch-over
frequency
Second PID action set
755
point
Second PID
756
proportional band
Second PID integral
757
time
Second PID
758
differential time
759
PID unit selection
Pre-charge fault
760
selection
Pre-charge ending
761
level
Pre-charge ending
762
time
Pre-charge upper
763
detection level
764
Pre-charge time limit
Second pre-charge
765
fault selection
Second pre-charge
766
ending level
Second pre-charge
767
ending time
Second pre-charge
768
upper detection level
Second pre-charge
769
time limit
*1
Differs according to types. (FM type/CA type)
*4
The setting is available when a vector control compatible option is installed. For the corresponding parameters of each option, refer to the
Instruction Manual of the option.
Setting range
Initial value
9999
0 to 9998, 9999
1 s
0 to 3600 s, 9999
9999
0 to 590 Hz, 9999
100%
1 to 100%
9999
0 to 590 Hz, 9999
100%
1 to 100%
0 to 590 Hz, 9999
9999
9999
5 to 50 ms, 9999
9999
10 to 999, 9999
9999
0 to 7, 9999
10 to 999, 9999
9999
9999
0 to 7, 9999
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
0
100, 101, 1000,
1001, 1010, 1011,
2000, 2001, 2010,
2011
0 to 590 Hz,
9999
9999
0 to 100%,
9999
9999
0.1 to 1000%,
100 %
9999
0.1 to 3600 s,
1 s
9999
0.01 to 10.00 s,
9999
9999
0 to 43,
9999
9999
0, 1
0
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0 %
0, 1
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
Parameter Name
Operation panel
774
monitor selection 1
Operation panel
775
monitor selection 2
Operation panel
776
monitor selection 3
4 mA input fault
777
operation frequency
778
4 mA input check filter
Operation frequency
779
during communication
error
Low speed range
788
torque characteristic
selection
Acceleration time in
791
low-speed range
Deceleration time in
792
low-speed range
Pulse increment
799
setting for output
power
Control method
800
selection
*4
Output limit level
801
Pre-excitation
802
selection
Constant output range
803
torque characteristic
selection
Torque command
804
source selection
Torque command
805
value (RAM)
Torque command
806
value (RAM, EEPROM)
807
Speed limit selection
Forward rotation
808
speed limit/speed
limit
Reverse rotation
809
speed limit/reverse-
side speed limit
Torque limit input
810
method selection
Set resolution
811
switchover
Torque limit level
812
(regeneration)
Torque limit level
813
(3rd quadrant)
Torque limit level
814
(4th quadrant)
815
Torque limit level 2
Torque limit level
816
during acceleration
Torque limit level
817
during deceleration
Easy gain tuning
818
response level setting
BASIC OPERATION
Setting range
Initial value
9999
1 to 3, 5 to 14, 17
to 20, 22 to 36,
38, 40 to 45, 50 to
9999
57, 61, 62, 64, 67,
71 to 75, 87 to 98,
100, 9999
9999
0 to 590 Hz,
9999
9999
0
0 to 10 s
0 to 590 Hz,
9999
9999
9999
0, 9999
9999
0 to 3600 s, 9999
0 to 3600 s, 9999
9999
0.1, 1, 10, 100,
1 kWh
1000 kWh
0 to 6, 9 to 12, 20,
20
100 to 106, 109 to
112
0 to 400%, 9999
9999
0
0, 1
0 to 2, 10, 11
0
0
0 to 6
1000%
600 to 1400%
1000%
600 to 1400%
0 to 2
0
*1
0 to 400 Hz
60/50 Hz
9999
0 to 400 Hz, 9999
0
0 to 2
0
0, 1, 10, 11
0 to 400%, 9999
9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
0 to 400%, 9999
9999
2
1 to 15
31