[4] Loosen the screws (four PT screws 4×8, indicated by
and
) on the maintenance cover B, and remove
the cover.
* Note:
Remove the maintenance cover B, in the same way
as the step [3].
Maintenance cover B also has two keyholes and two
fall protection screws.
Precaution
All screws for the maintenance cover are not neces-
sary to be removed from the unit, but if some screws
come out from the unit, tighten them to the original
positions.
[5] Remove the filters and inner cover.
[6] Open the snap-in cable clamp and remove the motor cable from it.
[7] Hold the handle and draw the Lossnay cores out from
the unit.
Precaution
When pulling out the Lossnay cores, make sure that
the motor cable is not caught. Otherwise, it might
damage the motor, circuit boards, and Lossnay cores.
Maintenance cover B
Motor cable
Lossnay core
─ 37 ─
Filter
Inner cover
Cable clamp
Handle