MAD / MAF Asynchronous Housing Motors
Parameter
Pressure drop at Q
min
Constant for determining the pres‐
sure drop with water as cooling me‐
dium
Required coolant flow for P
V
Coolant channel volume
Maximum allowed input pressure
4.10.4
Motor characteristic curves MAF160C
Symbol
Unit
0050
Δp
bar
K
-
Δp
Q
l/min
5.0
min
V
l
cool
p
bar
max
1)
Please note the information on the specified parameters at the
beginning of this chapter
Tab. 4-30:
Technical data MAF160C
Fig. 4-90:
Motor characteristic curve MAF160C-0050
MAF160C
0100
0150
0.1
0.01
5.3
5.4
0.99
6.0
R911295781_Edition 11 Bosch Rexroth AG
97/265
Technical data
0200
0.004
6.0