Calling Up Information About The System - Bosch HPC 400 Operating Instructions Manual

User interface
Table of Contents

Advertisement

6

Calling up information about the system

The current system values and the active operating conditions
can be displayed easily via the info menu. No changes can be
made in this menu.
The info menu is adapted to your system automatically. Some
menu items are only available if the system has been set up
accordingly and the user interface has been set correctly
( Chapter 2.1, page 3).
Info
Heating/Cooling
Heating circuit 1 ... 4
Operating mode heating/
Set room temp.
Actual room temp.
Actual flow temp.
DHW
Set temp.
Actual temp.
Pool
Pool set point temp.
Actual temp. pool
Operating data
Operating hours Control
Heat pump 1 ... 2
Output additional heat
Operating hours
Operating hours
Operating hours
Op. hours for comp. pool
Number of starts heating
Number of starts cooling
Number of starts DHW
Number of starts pool
Fig. 5
Menu structure of the info menu
1)
Only available if a temperature sensor or remote control
is installed in the reference room of the corresponding
heating circuit.
HPC 400
CLIMATE CONTROL SYSTEMS
▶ If the standard display is active, press the info key to open
▶ Turn the selector to select the required menu, e.g. DHW.
▶ Press the selector to open the selected menu.
▶ Turn the selector to display more available information.
▶ Press the Back key to return to the higher menu level.
▶ Press and hold the Back key to return to the standard
Consumed energy
Heat pump 1 ... 2
Total
Elec. add. heater
1)
...
Compressor
...
Output produced
Total output produced
Heating output produced
DHW output produced
Cooling output produced
Pool output produced
Solar
Solar sensors
Solar yield
Solar thermal system
Gross-collector area 1
Solar pump
Gross collector area 2
Solar circ.pump 2
Reload pump
Therm. disinfection pump
Outdoor temp.
Outdoor temp. curve
Outdoor temp.
VOGEL
NOOT
&
Calling up information about the system | 31
the info menu.
display.
Internet
IP connection
Server connection
SW version
Login data
MAC address
System information
Heat pump status
Status refrigerant circuit
Status additional heat
Elec. add heater output
Status mixed additional heat
El. DHW additional heater
Electricity company block
PV
Smart grid
Actual mode
...
Heat pump 1 ... 2
Heat pump 1 ... 2
Heat pump 1 ... 2
Add. heat source
Mixing valve
Heat pump 1 ... 2
6 720 811 136-102.2O
6 720 817 986 (2015/07)

Hide quick links:

Advertisement

Table of Contents
loading