3.6.1. MP-BB3 1-PSU / AC Mains

For the 1-PSU configuration, connect the device to the PSU1 slot. Do not use the PSU2 slot:

3.6.2. PSU Redundancy, AC mains, RF Output Power (TPO)

For AC mains M110 (mains less than 160VAC), the EC704MP-BB3 works with only 1 PSU but with an
output power of 50%. The Control Module CM9001 will show the "REDUCTION POWER" alarm.
For AC mains M220/B220 (187 ~ 253VAC), the EC704MP-BB3 works with only 1 PSU but with an
output power of 70%. The Control Module CM9001 will show the "REDUCTION POWER" alarm.
EC704MP-BB3 - MAXIMUM PROGRAMMED POWER: 350W (ATSC 1.0)
INPUT VOLTAGE
100 ~187 VAC
100 ~187 VAC
187 ~253 VAC
187 ~253 VAC
EC704MP-BB3 - MAXIMUM PROGRAMMED POWER: 500W (ATSC 1.0)
INPUT VOLTAGE
100 ~187 VAC
100 ~187 VAC
187 ~253 VAC
187 ~253 VAC
EC702MP-BB3 - MAXIMUM PROGRAMMED POWER: 250W (ATSC 1.0)
INPUT VOLTAGE
100 ~253 VAC
100 ~253 VAC
NUMBER OF PSU
OPERATING
1
2
1
2
NUMBER OF PSU
OPERATING
1
2
1
2
NUMBER OF PSU
OPERATING
1
2
E-Compact MP-BB3 Series
OUTPUT POWER
50%
100%
100%
100%
OUTPUT POWER
50%
100%
70%
100%
OUTPUT POWER
100%
100%