Split Rooftop Unit Product Overview; General Data - LG MULTI V ARNU363DDA4 Installation Manual

Split rooftop unit
Hide thumbs Also See for MULTI V ARNU363DDA4:
Table of Contents

Advertisement

Table 1: ARNU363~723DDA4 General Data.
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Heating Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Entering Mixed Air
Cooling Max. (°F WB)
Heating Min. (°F DB)
2
Unit Data
Refrigerant Type
3
Refrigerant Control
Sound Power
dB(A) (H/M/L)
4
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
5
Fan
Type
Motor
Motor/Drive
Airflow Rate H/M/L (CFM) Standard Mode
External Static Pressure (in. wg) Standard Mode
External Static Pressure (in. wg)
Piping
Liquid Line (in., O.D.)
High Pressure Vapor Line (in, OD)
Low Pressure Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
Filtration
Outdoor
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national
codes.
This unit comes with a dry nitrogen charge.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change
without notice. Current certified ratings are available at www.ahridirectory.org.
Max power input is rated at maximum setting value.
1
Low ambient performance with LGRED° heat technology is included in Multi V 5 Air
2
ARNU363DDA4
36,000
640
110 / 130 / 150
38,000
640
110 / 130 / 150
76
59
R410A
EEV
66 / 63 / 60
472
494
1
1200 / 1000 / 800
1.7
0.2 - 1.7
3/8 Brazed
1/2 Brazed
5/8 Brazed
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
PRODUCT OVERVIEW
ARNU483DDA4
ARNU603DDA4
48,000
60,000
700
760
120 / 150 / 260
130 / 250 / 330
52,000
71,000
700
760
120 / 150 / 260
130 / 250 / 330
76
76
59
59
R410A
R410A
EEV
EEV
67 / 64 / 61
68 / 65 / 62
472
472
494
494
2 x 18
3D Plug
1
ECM (Electronically Commutated Motor) / Direct
1400 / 1200 / 950 1700 / 1300 / 1000
1.6
1.5
0.2 - 1.6
0.2 - 1.5
3/8 Brazed
3/8 Brazed
1/2 Brazed
5/8 Brazed
5/8 Brazed
3/4 Brazed
1, Plain
2" Merv8 (16" x 20") x 4 each
Source Units produced after February 2019.
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
3
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4
All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded
5
and must comply with applicable local and national codes. Ensure the communication
cable is properly grounded at the main outdoor unit only.
communication cable at any other point.

General Data

ARNU723DDA4
72,000
770
140 / 260 / 350
80,000
770
140 / 260 / 350
76
59
R410A
EEV
69 / 66 / 63
472
494
1
1
1800 / 1400 / 1100
1.4
0.2 - 1.4
3/8 Brazed
5/8 Brazed
3/4 Brazed
Do not ground the ODU-IDU
11