Setting Screen - Panasonic AG-HMX100E Operating Instructions Manual

Digital av mixer
Table of Contents

Advertisement

Setting Screen

When setting up this unit or adjusting functions, you need to check the current settings on the LCD screen.
The following shows the basic configuration of the setting screen.
4
5
1 Joystick, rotary Z control settings, and 3D display
area
Shows the setting values of the joystick and rotary Z
control; X, Y, and Z values during position setting and
P
, P
, and C GAIN values during color setting.
B
R
When this unit is in 3D mode ( page Vol. 2-25), [3D] is
displayed.
2 Audio level meter
Indicates the audio output level.
3 Error Message
An error message appears in the following cases.
Message
Condition and Action
FAN STOP
The fan has stopped from any cause.
Immediately turn off the power and
request a service call ( page 39).
CHANGE HDMI
HDMI input source in the format other
FORMAT
than the system formats ( page 19)
CHANGE HDMI1
available for this unit is being
FORMAT
connected to this unit.
CHANGE HDMI2
CHANGE HDMI FORMAT: Input
FORMAT
sources of both HDMI IN
connectors are in unavailable
formats.
CHANGE HDMI1 FORMAT:
Input source of the HDMI IN 1
connector is in unavailable format.
CHANGE HDMI2 FORMAT:
Input source of the HDMI IN 2
connector is in unavailable format.
Change the system format setting or
the input source setting.
20
1
POS.
X 128
Y 128
Z 196
EVENT
ME TIME
00
2:00
E
VIDEO EFFECTS
MOSAIC
OFF
DEFOCUS
LEVEL
OFF
MONO
OFF
2
FAN STOP
PATTERN
INT
3044 WHT
F
CH A
SIZE
XY
0
0
6
 NOTE
The "FAN STOP" error message is also displayed on the
multi-view screen. However, since the multi-view screen
does not open when this unit is in 3D mode ( page
Vol.2-25), no error message is displayed even if the fan
stops. Pay attention to a message which will appear on the
LCD.
If two types of errors occur at the same time, "FAN STOP"
is displayed preferentially.
4 Event number, transition time, pattern number, and
internal video display area
EVENT: Shows the event number ( page Vol.2-20).
ME TIME: Shows the setting value of transition time
( page 35); DSK TIME value during downstream
key setting ( page 37) and FADE TIME value
during fade setting ( page 38).
To change the TIME type, press the applicable
transition time setting button (ME, DSK, or FADE) to
turn on.
PATTERN: Shows the number of the currently selected
pattern ( page 35).
INT: Shows the type of the currently selected internal
(internally generated) video ( page 28).
5 Menu title, related information, rotary 1 to 5
parameter display area
Shows the title of the currently selected menu
( page 21) (e.g., VIDEO EFFECTS), bus settings
(A/B), related information (color settings, etc), and
setting positions of rotary 1 to 5 controls.
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag-hmx100pAg-hmx100Ag-hmx100pj

Table of Contents