Download Print this page

Panasonic SD-206 Service Manual page 124

Advertisement

6.2.2 RISE mode confirmation test.
TOP PREVIOUS NEXT
1. From the
Initial test mode
2. The LCD indication shown in
operation LED (Red) will light up.
3. Next, the temperature will be adjusted at relay current flow ratio of 3.2/32 (10 percent) in order
to maintain a bread case temperature of approximately 95°F (35.0°C)./In order to measure the
rising temperature of the Bread pan thermometer./Allow the unit to sit in this condition for at
least approximately one hour, check the temperature in the bread pan with a mercury
thermometer./The unit is functioning properly if the temperature is between 88°F (31°C) and
102°F (39°C).
4. To return to
TOP PREVIOUS NEXT
, press the "TIMER" pad once.
RISE mode confirmation test LCD
Initial test mode
, press "START/STOP" pad once.
RISE mode confirmation test LCD
will appear, and the

Advertisement

loading