Troubleshooting - Husqvarna DC 6000 Operator's Manual

Hide thumbs Also See for DC 6000:
Table of Contents

Advertisement

Available languages

Available languages

1. Pull out the Longopac bag (A) and attach a cable tie
(B) to close the new Longopac bag.
B
2. Shake down the dust in the used Longopac bag.
Troubleshooting schedule
Issue
The motor does not start.
The product make a low sound
when it is on.
The product blows instead of
sucking.
94
A

Troubleshooting

Cause
No power.
The cable is defective.
The power switch is defective.
Phase error. Only two phases present.
Dust in the motor impellars.
The motor is defektive.
The phase relay is defective.
3. Attach a cable tie 10 cm/3.9 in. below the first cable
tie to close the used Longopac bag. Cut off the
Longopac bag between the cable ties.
4. If the remaining part of the Longopac bag cassette
is too small to prepare a new Longopac bag, install
a new Longopac bag cassette. Refer to
new Longopac dust bag on page 93 .
5. Obey local regulations for disposal of the full
Longopac bag.
To install a
Solution
Plug in machine.
Make sure that the power
source work and that there is
power in the left side contac-
tors.
Replace the cable.
Replace the power switch.
Turn off the product and contact
a electrician.
Turn off the product and contact
a electrician.
Turn off the product and contact
your service agent.
Turn off the product and contact
a electrician. Switch L1 and L3
on the motor and do a test of
the suction.
1883 - 001 - 01.06.2022

Advertisement

Table of Contents
loading

Table of Contents