Network Vp E Satellites - Toro Lynx Manual

Golf irrigation products
Table of Contents

Advertisement

Network VP
E
Features
• Display supports 7 languages: Chinese, English, French,
Italian, Japanese, Korean and Spanish
• Station based flow management reduces nighttime water
window and optimizes pump capacity.
• Variable Length (VL) communication reduces download
time by up to 80%.
• Intuitive user interface with backlit display for better low-
light viewing.
• Optional output switches and surge protection
• Sturdy plastic pedestal
• Supports wireline or radio communications
• Supports hybrid communication (wireline and radio) for
increased flexibility and cost effectiveness.
• 16 irrigation programs
• Pause, Resume and Stop functions
• Supports run times from 1 second to 23:59:59
• Percent adjust from 1% to 900% (Station, Program,
Satellite)
• Each output can be defined as an irrigation station or
general application switch
• Non-volatile memory retains program information and
satellite settings during power-off conditions. Battery back-
up retains the satellite date and time
• 16-64 stations in 8-station increments
• Individual station control and the ability to run up to 16
stations simultaneously
• Backwards compatible with Network 8000 satellites.
Central Control Compatibility
• The Toro® Lynx® Central Control System
Description
10X
100— Network VP
Satellite
16—16 Stations
E
(115/230 VAC Input)
32—32 Stations
48—48 Stations
109— Network VP
Satellite
E
64—64 Stations
(100/200 VAC Input)
Example: When ordering a 24-station, 2-way wire VP
Radio option not available in all locations, please check with your Toro representative for availability.
Satellites
Pedestal available in standard
Green, Desert Sand and Tree Bark
Specifying Information—Network VP
Configuration
Cabinet
XX
X
24—24 Stations
P—Plastic, Green
40—40 Stations
T—Desert Sand
56—56 Stations
B—Tree Bark
Satellite in a plastic cabinet with large-capacity terminal block, additional surge and switches,
E
you would specify: 100-24P6M4
Electrical Specifications
Input Power:
• 108 V ac to 132 V ac, 60 Hz
• 0,20 amps (no load) 115 V ac
• 1,20 amps (max load) 115 V ac
• 216 V ac to 264 V ac, 50 Hz
• 0,10 amps (no load) 230 V ac
• 0,60 amps (max load) 230 V ac
Output Power:
• 24 V ac
• 3,0 amps (max total load)
• UL Listed
Additional Specifications
• Operating temperature: -10°C to 60°C (15°F to 140°F)
• Storage temperature: -30°C to 65°C (-22°F to 149°F)
• Humidity: 0% to 95% RH (non-condensing)
Dimensions
• Plastic Cabinet: 41cm W x 99cm H x 41cm D
(17" W x 40" H x 16" D)
• Metal Cabinet: 33cm W x 91cm H x 33cm D
(13" W x 36" H x 13" D)
Warranty
• 1 Year
Satellites
E
10X-XXX6XX
Output
Comm.
6
X
6—24 VAC
M—2-Way Wire Modem
R—UHF Radio
Options
X
0—No Options
3—Large-capacity Terminal Block & Switches
4— Large-capacity Terminal Block w/Add'l Surge &
Switches
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents