Rev0 10.03.24

1. Scope

This manual is applied to the on-site installation of OCR scanner HT-4139.
The OCR scanner HT-4139 can be operated by connecting to the PC with the USB cable.

2. Tools and Parts

(1) Standard Tools
(2) Circuit Tester
(3) Ethanol, Gauze

3. Installation Time

About 60 minutes

4. Procedure

Caution
Due to the transportation in winter, there might be dew condensation on the device.
If you power on just after unpack and install the device, glasses might be misted up and it may cause of read error.
In this case, turn off the power and after a few hours power on again.

Installation Work

Preparation
5.1
Confirm the requirement
5.2
for the host
5.2.1
OS, Memory, Required
Disk Capacity
Confirm the requirement
5.2.2
for the USB
5.3
Installation of the Image
Scanner Driver
5.4
Test Scanning
5.5
Delevery
5.6
Check with Data Sheet for
on-site Installation
(Finish)
Unpack the OCR scanner container and set the device at the place where
customer specified.
Check the components, appearance, and the power supply systems.
Installation of the OCR scanner hardware.
Do not connect the USB cable to the PC.
NOTICE
Check hardware and software of the host systems to set up the Image Scanner
Driver.
As the OCR scanner will not work with the OS that does not support the USB,
need to confirm the host systems.
Install the Image Scanner Driver to the PC.
At this step. connect USB cable to the PC now.
NOTICE
Ensure the OCR scanner can be operated properly by the host systems.
Request the customer to confirm the installation work and explain how to operate the
device and about safety precautions.
Ensure all work has been completed.