5. Insert the battery pack into the slot in the orientation
shown below.
The CHARGE lamp will light up and charging will
begin.
NOTE:
 Insert an appropriate size of the battery pack
according to the partition's orientation. Failure to
do this may damage the battery pack or affect
charging operation.
 Place the battery pack firmly.
 Charge the battery pack on a flat, steady surface.
The CHARGE lamp indicates a charging status.
CHARGE lamp
OFF
Red
Green
Blinking red
6. After charging is completed, remove the battery pack from the battery charger.
7. Disconnect the power cord from the AC outlet.
Charging time
To charge an empty battery pack:
Battery pack
B-EP802-BT-QM-R
B-EP804-BT-QM-R
B-FP803-BT-QM-R
B-FP803-BTH-QM-R
• Charging time may differ depending on the condition of the battery pack or the operating
temperature.
• After the CHARGE lamp turns from red to green, the battery charger may continue to charge
the battery pack for up to one more hour until the full charge level (95% or more).
NOTE:
1. Battery packs should be charged on condition that both ambient temperature and battery
temperature fall within a range of 0 °C to 40°C.
2. The battery charger will get warmer during charging (room temperature + about 30°C). This is
not abnormal.
3. If the over discharge protector has been operated on a battery pack, the CHARGE lamp may
not light for a while. Leave the battery charger and the battery pack alone for a few minutes.
Stop using the battery pack if the CHARGE lamp does not light at all as the battery pack may be
faulty.
4. The battery pack can be removed from the battery charger while charging is in progress.
However, the battery lasting time depends on the charging time.
5. After the charging is completed, do not leave the battery pack in the charger too long. The
battery pack gradually discharges.
6. Periodically clean the charger terminals with a soft dry cloth.
State
Unconnected.
Charged.
Completed.
Abnormal state
about 3 hours
(Until the min. of 85% of the nominal capacity is charged.)
5
CHARGE Lamp
NOTE:
The green light does not go off until the battery
pack is removed from the slot.
Charging time
Battery Pack
Partition