Panasonic SF4D-A18 Instruction Manual

Safety light curtain type 4
Hide thumbs Also See for SF4D-A18:
Table of Contents

Advertisement

Quick Links

WUME-SF4D01-4
2020.1
panasonic.net/id/pidsx/global
Safety Light Curtain Type 4
SF4D-□-01
Instruction Manual
Ministry of Health, Labour and Welfare approved device
Press machines:
Model examination No. TA601 (SF4D-F,-H), TA600 (SF4D-A)
Shearing machines: Model examination No. TA603 (SF4D-F,-H), TA602 (SF4D-A)

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic SF4D-A18

  • Page 1 Safety Light Curtain Type 4 SF4D-□-01 Instruction Manual Ministry of Health, Labour and Welfare approved device Press machines: Model examination No. TA601 (SF4D-F,-H), TA600 (SF4D-A) Shearing machines: Model examination No. TA603 (SF4D-F,-H), TA602 (SF4D-A) WUME-SF4D01-4 2020.1 panasonic.net/id/pidsx/global...
  • Page 2 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 3 Thank you very much for purchasing Panasonic Industrial Devices SUNX's Safety Light Curtain, SF4D-□-01. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
  • Page 4: Table Of Contents

    2-5-4 Basic Wiring ··········································································64 2-5-5 Wiring for Manual Reset (Interlock is Valid) ··································67 2-5-6 Wiring for Series Connection ····················································69 2-5-7 Wiring Configuration for Valid External Device Monitor Function ·······71 2-5-8 Wiring Configuration for Valid Muting Function ······························73 2-6 Adjustment················································································ 75 2-6-1 Beam Adjustment ···································································75 2-6-2 Operation Test ·······································································79 2-6-3 Indicator Operation ·································································81 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 5 6-3-10-5 No Dead-Space Beam Adjustment Mounting Bracket MS-SFD-3-6 ······················································· 161 6-3-10-6 SF4B-G Compatible Mounting Bracket MS-SFD-4BG · 162 Chapter 7 Other Information ···························································· 163 7-1 Glossary················································································· 164 7-2 CE Marking Declaration of Conformity ·········································· 166 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 6 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 7: Chapter 1 Introduction

    Chapter 1 Introduction 1-1 Safety Cautions ···········································································8 1-2 Applicable Standards / Regulations ················································ 12 1-3 Confirmation of Packed Objects ···················································· 14 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 8: Safety Cautions

    When using as a safety device for a press machine or paper shearing machine in Japan When using as a safety device for a press machine or paper shearing machine in Japan, always at- tach the protective tube SFPD-A10 (option) to the cable. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 9 For details, refer to “2-3-4 Preventing Mutual Interference”. ● Do not use this device in a reflective configuration. ● The corresponding emitter and receiver must have the same serial No. and be correctly oriented. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 10 ● Clean this device with a clean cloth. Do not use any volatile chemicals. ♦ Others ● Never modify this device. Modification may cause the device not to detect objects, result- ing in death or serious injury. ● Do not use this device to detect objects flying over the detection area. ● Do not use this device to detect transparent objects, translucent objects or objects smaller than the specified minimum object to be detected. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 11 <Shearing machine> Item Specification Machine type Shearing machine with an emergency stop mechanism and restart prevention mechanism Shearing thickness 200mm or less Shearing width 5,000mm or less Blade length 5,500mm or less © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 12: Applicable Standards / Regulations

    ANSI/UL 61496-1/2 (Type 4) CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2 <Regulations in US> OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 For Machinery Directive, type certification a Notified Body TÜV SÜD has been acquired. For the standards in US / Canada, TÜV mark by a Notified Body TÜV SÜD has been ac- quired. <Standards in China> GB 4584 <Reference> The conformance of this device to JIS, OSHA and ANSI is based on our self-evaluation. TÜV mark indicates that this device conforms to the NRTL certification (such as UL) in the US and CSA certification in Canada. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 13 TA602 (shearing machine) are indicated on SF4D-A□-01 units. ● When only this device is used, or when this device is used in combination with the specified control unit, a different the model examination No. applies. When used in combination with the specified control unit, the model examination No. is indicated on the control unit. ● When used in combination with the specified control unit, this device cannot be used for a shear- ing machine. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 14: Confirmation Of Packed Objects

    SF4D-F□-01: SF4B-TR14 (ø14 × 220mm), SF4D-H□-01: SF4B-TR25 (ø25 × 220mm) □ Quick Instruction Manual (Japanese, English, Chinese) 1 pc. for each language □ General Information for Safety, Compliance, and Instructions (23 languages) 1 pc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 15: Chapter 2 Before Using The Device

    2-5-4 Basic Wiring ··········································································64 2-5-5 Wiring for Manual Reset (Interlock is Valid) ··································67 2-5-6 Wiring for Series Connection ····················································69 2-5-7 Wiring Configuration for Valid External Device Monitor Function ·······71 2-5-8 Wiring Configuration for Valid Muting Function ······························73 2-6 Adjustment················································································ 75 2-6-1 Beam Adjustment ···································································75 2-6-2 Operation Test ·······································································79 2-6-3 Indicator Operation ·································································81 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 16: Features

    ● Upper application indicator and lower application indicator make beam alignment easy. ● For details on options, refer to “6-2 Options”. 2-2 Parts of the Device Receiver Indicator Emitter Beam axis Indicator Indicator Gray cable (with black line) Indicator Indicator Gray cable © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 17 Lower application indicator Lower application indicator Emitter: Light emission intensity control indicator Stable light Receiver: reception indicator Function setting indicator Digital indicator Emitter: Test indicator Frequency indicator Receiver: Interlock indicator Emitter: Operation indicator Receiver: OSSD indicator © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 18 Interlock activated: Lights yellow “ ”, All other times: Turns OFF [LOCK] OSSD indicator (Red / Green) Control output (OSSD 1 / 2) OFF: Lights red “ ” [OSSD] Control output (OSSD 1 / 2) ON: Lights green “ ” Notes: 1) In the case of optical synchronization, the upper application indicator and lower application indicator on the emitter remain OFF. 2) Names in brackets [ ] are names that are indicated on the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 19 Monitoring operations ○ ○ software Checking histories such as errors ○ Communication module Collating settings SF4D-TM1 (option) Reading and writing settings Copy function Communication module SF4D-TM1 (option) Saved data initialization function ○: Available, -: Unavailable © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 20: Protection Area

    Bottom Sensing range (effective) <Example of correct sensing area setup> Sensing Protective Dangerous Dangerous area structure part part Sensing area <Example of incorrect sensing area setup> Sensing Sensing Dangerous Dangerous area area part part © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 21: Safety Distance

    The safety distance is calculated using the equations given on the following pages when a per- son moves perpendicularly (normal intrusion) into the sensing area of the device. Safety distance S Sensing area Dangerous part Intrusion direction © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 22 SF4D : Maximum response time of machine (sec.) : Response time of device (sec.) SF4D C: Additional distance calculated from the minimum sensing object of the device (mm) C = 850 (mm) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 23 This meets condition 3) above, and thus S = 1,600 × T + 97.6 = 1,600 × 0.4 + 97.6 = 737.6 This meets condition 5) above, and thus the safety distance is 737.6 (mm). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 24 = 129.2mm = 3.4 × (d − 0.275) (inches) ≈ 3.4 × (d − 7) (mm) d: Diameter of minimum sensing object 0.552 (inches) ≈ 14 (mm) SF4D-F□-01 Diameter of minimum sensing object 0.985 (inches) ≈ 25 (mm) SF4D-H□-01 Diameter of minimum sensing object 1.772 (inches) ≈ 45 (mm) SF4D-A□-01 <Reference> ● When the floating blanking function is used, the minimum sensing object becomes larger. According to ANSI B11.19, D = 900mm (3ft) when d > 63.5mm (2.5 inches). ● Calculated using 1 (inch) = 25.4 (mm). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 25 2. Install the auxiliary beam channels (sub sensors) so that they are horizontal with respect to the front line of the bolster, and in a position that is about the height of the worker's waist. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 26 Risk of death or serious injury if auxiliary beam channels (sub sensors) are not in- stalled. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 27 Risk of death or serious injury if auxiliary beam channels (sub sensors) are not in- stalled. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 28 > 14 to 20mm 80mm Possible > 20 to 30mm 130mm > 30 to 40mm 240mm Not possible > 40mm 850mm On a press machine, if the interlock (start-restart interlock) function of the device or a safety controller is used, calculate with C = 0. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 29: Effects Of Reflective Surfaces

    Permissible installation distance A When 0.2 to 3m 0.131m When 3 to 15m L / 2 × tan5 ≈ L × 0.0437 (m) Permissible device installation distance from reflective surface Installation allowed area Installation prohibited area Distance L (m) between emitter and receiver © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 30: Preventing Mutual Interference

    ● When connecting devices in series, connect emitters to emitters and receivers to receivers. If an emitter is connected to a receiver, the device will change to the lockout state. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 31: Preventing Mutual Interference By Device Placement

    1) Side-by-side placement 2) Vertical placement Emitter Receiver Receiver Emitter Emitter Receiver Receiver Emitter 3) Front and back placement 4) With a light-blocking barrier Receiver Receiver Emitter Receiver Emitter Emitter Emitter Receiver Blocking object © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 32 The emitter and receiver cables must be oriented in the same direction. Risk of malfunctioning if the cables are not in the same oriented in the same direction. Cable Cable Cable Cable © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 33: Mounting

    ● Unless otherwise indicated, the mounting procedures that follow are for both the emitter and re- ceiver. Prior to mounting, prepare mounting holes in the mounting surface as described in “6-3 Dimensions”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 34: Using Beam Adjustment Mounting Bracket Ms-Sfd-1-□ (Option) ·34

    Loosen the two hexagon-socket head bolts with washers [M4 (length 8mm), opposing faces 3mm] and remove the bracket. Change the orientation of the mounting bracket, and tighten the two hexagon-socket head bolts with washers [M4 (length 8mm), opposing faces 3mm]. Tighten to a torque of 1.5N·m or less. Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] (Included with MS-SFD-1-□) Mounting bracket Base bracket © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 35 Step 3 Install the beam adjustment mounting bracket on the mounting surface with a hexagon- socket head (purchase separately). <MS-SFD-1-5> <MS-SFD-1-6> <MS-SFD-1-8> Hexagon-socket head bolt Hexagon-socket head bolt Hexagon-socket head bolt [M5 (purchase separately)] [M6 (purchase separately)] [M8 (purchase separately)] Hexagon-socket head bolt [M8 (purchase separately)] © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 36: Using Intermediate Supporting Bracket Ms-Sfb-2 (Option) ·36

    Tighten to a torque of 1.2N·m or less. For the mounting position of the intermediate supporting bracket, refer to “6-3 Dimen- sions”. This device <Side mounting> Slide and remove the fixing fitting of the intermediate supporting bracket from the base bracket. Change the direction of the fixing fitting, and engage the notches on the fixing fitting with the rails on the base bracket. Notch on fixing fitting Notch on fixing fitting © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 37 Note: When the number of beam axes is SF4D-F□-01: 111 or more beam axes, SF4D-H□-01: 56 or more beam axes, SF4D-A□-01: 28 or more beam axes, one set is required. CAUTION The intermediate supporting bracket MS-SFB-2 is not intended to secure the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 38: Using No Dead-Space Beam Adjustment Mounting Bracket Ms-Sfd-3-6 (Option) ·38

    Step 2 Partially loosen the hexagon-socket head bolt (M5, black) for light curtain fastening. Hexagon-socket head bolt for light curtain fastening (M5, black) CAUTION Do not remove the hexagon-socket head bolt (M5, black) that fastens the light curtain from this product. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 39 (M5, black) This device CAUTION Firmly fasten the product to the no dead-space beam adjustment mounting bracket. Risk of prod- uct falling and causing injury or product damage. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 40 Step 2 While pushing the product against the hexagon-socket head bolt side, remove the no dead-space beam adjustment mounting bracket. Hexagon-socket head bolt This device No dead-space beam adjustment mounting bracket © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 41: Using Sf4B-G Compatible Mounting Bracket Ms-Sfd-4Bg (Option) ·41

    <Side mounting> Loosen the two hexagon-socket head bolts with washers [M4 (length 8mm), opposing faces 3mm] and remove the bracket. Change the orientation of the mounting bracket, and tighten the two hexagon-socket head bolts with washers [M4 (length 8mm), opposing faces 3mm]. Tighten to a torque of 1.5N·m or less. Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] (Included with MS-SFD-4BG) Mounting bracket Base bracket © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 42 Mounting Step 3 Install the beam adjustment mounting bracket on the mounting surface with a hexagon- socket head bolts (purchase separately). Hexagon-socket head bolt Hexagon-socket head bolt [M5 (purchase separately)] [M8 (purchase separately)] © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 43: Installing The Bottom Cap Cables (Option)

    Discrete wire type 5-core SFD-CCB10-S Connector type SFD-CB05-S 0.5m SFD-CCB3 SFD-CCB7 Discrete wire type SFD-CCB10 8-core SFD-CCB15 SFD-CB05 0.5m Connector type SFD-CB5 SFD-CB10 SFD-CCB3-MU Discrete wire type SFD-CCB7-MU 12-core SFD-CCB10-MU Connector type SFD-CB05-MU 0.5m © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 44 Bottom cap cable (Option) Connector Cable This device Connector Groove Step 2 Tighten the two M2.6 screws. Tighten to a torque of 0.3N·m or less. M2.6 screw (Included with bottom cap cable) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 45: Adding And Removing Sensors (Series Connection)

    1. Do not run the cable before you have fastened the connector with the M2.6 screws. Fastened with M2.6 screw Not fastened with M2.6 screw 2. Make sure the connector is completely inserted before fastening with the M2.6 screws. Without gap With gap © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 46 Step 3 Tighten the two M2.6 screws. Tighten to a torque of 0.3N·m or less. M2.6 screw M2.6 screw (Included with cable for series (Included with cable for connection) series connection) Sub sensor Main sensor (Bottom) (Top) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 47 When using as a safety device for a press machine or paper shearing machine in Japan, always at- tach the protective tube SFPD-A10 (option) to the cable. <Removing the series connection cable> Step 1 To disconnect the series connection cable, reverse the procedure for <Connecting the series connection cable>. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 48: Attaching The Protective Tube

    About 33mm Step 2 Separate the protective tube as shown below. Step 3 Insert the cable. Step 4 Reinsert the protective tube to restore to its original state. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 49: Mounting And Removing The Front Protective Cover

    Front protective cover (wide type) FC-SFDH□ (option) This device <Removing wide type FC-SFDH□> Expand both sides of the front protective cover to the right and left and then remove the cover from the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 50 <Removing slim type FC-SFDH□-S> Insert your fingers into the gaps on the top and bottom of the front protective cover and slowly remove the cover from the device. CAUTION Do not apply excessive force when removing the front protective cover from the device. Doing so may break the cover. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 51: Wiring

    5) If surges occur, take countermeasures such as connecting a surge absorber to the source of the surges. 6) The power unit must be a CLASS 2 compliant unit. (When TÜV mark compliance is required.) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 52: Input / Output Circuit Diagrams And Output Waveforms

    24V DC (White) Control output 2 (OSSD 2) − (Pale blue) Output polarity setting / Lockout release input (Blue) 0V Internal circuit Users’ circuit Switch S1 ● Test input Vs to Vs − 2.5V (sink current 5mA or less): Emission halt, Open: Emission (Note) Note: Vs is the supply voltage. <Reference> K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 53 Users’ circuit Receiver (Brown) +V (Pale blue) Output polarity setting / Lockout release input (Black) Control output 1 (OSSD 1) 24V DC − (White) Control output 2 (OSSD 2) (Blue) 0V Internal circuit Users’ circuit Switch S1 ● Test input 0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission <Reference> K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 54 ● Test / Reset input Manual reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note), Open: Emission Auto reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt ● Interlock setting input, External device monitor input Vs to Vs − 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid Note: Vs is the supply voltage. <Reference> K1, K2: External device (forcible guide relay or magnetic contactor) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 55 Internal circuit Users’ circuit Switch S1 ● Test / Reset input Manual reset …0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission Auto reset …0 to +2.5V (source current 5mA or less): Emission, Open: Emission halt ● Interlock setting input, External device monitor input 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid <Reference> K1, K2: External device (forcible guide relay or magnetic contactor) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 56 6.8kΩ 470Ω 0.1μF (Pale purple) External device monitor input K1 K2 0.1μF 6.8kΩ (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) (Red) Auxiliary output 2 (Pale blue) Output polarity setting / Lockout release input Load (Gray) NC (Blue) 0V Internal circuit Users’ circuit © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 57 Wiring Switch S1 ● Test / Reset input Manual reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note), Open: Emission Auto reset …Vs to Vs − 2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt ● Interlock setting input, Override input, Muting input A / B, External device monitor input Vs to Vs − 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid Note: Vs is the supply voltage. <Reference> K1, K2: External device (forcible guide relay or magnetic contactor) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 58 (Pale purple) External device monitor input K1 K2 470Ω 6.8kΩ 6.8kΩ 470Ω 0.1μF (Pink) Muting input A 6.8kΩ 6.8kΩ 470Ω 0.1μF (Yellow) Muting input B 6.8kΩ 0.1μF (Blue) 0V Internal circuit Users’ circuit © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 59 Switch S1 ● Test / Reset input Manual reset …0 to 2.5V (source current 5mA or less): Emission halt, Open: Emission Auto reset …0 to 2.5V (source current 5mA or less): Emission, Open: Emission halt ● Interlock setting input, Override input, Muting input A / B, External device monitor input 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid <Reference> ● K1, K2: External device (forcible guide relay or magnetic contactor) ● For wiring, refer to 2-5-4 and following sections. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 60 50ms or less Light blocked (Note 1) Control output 1 (OSSD 1) 50µs 80µs Control output 2 (OSSD 2) 80µs (Note 2) 50µs 80µs 100µs Notes: 1) Depends on main cycle: 2.6 to 8.9ms 2) Extended up to a maximum of 300μs when the load is a capacitance load. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 61: Cable Wiring / Connections / Extension And Connector Pinouts

    Cable with connector on one end Cable with connector on both ends B side side side Side A connector (emitter/receiver common) Side B connector (emitter/receiver common) <5-core> <8-core> <12-core> <5-core> <8-core> <12-core> © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 62 Pale blue Output polarity setting / Lockout release input White Control output 2 (OSSD 2) Brown 24V DC Black Control output 1 (OSSD 1) Pale purple External device monitor input Gray (with black line) / Receiver Black Orange Synchronization + Orange / Black Synchronization - Blue Pale blue Output polarity setting / Lockout release input © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 63 ● Connectors for the emitter are gray, and connectors for the receiver are black. ● For details on cables with a connector on one end and cables with a connector on both ends, refer to “6-2 Options”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 64: Basic Wiring

    (Pink) Test input (Brown) +V (Pale blue) Output polarity setting / Lockout release input 24V DC − (Blue) 0V (Brown) +V (Black) Control output 1 (OSSD 1) 24V DC (White) Control output 2 (OSSD 2) (Pale blue) Output polarity setting / Lockout release input − (Blue) 0V Gray cable (with black line) *Symbols K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 65 (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) Gray cable (with black line) (Pale blue) Output polarity setting / Lockout release input (Blue) 0V Interlock function Invalid (auto reset) External device monitor function Invalid Auxiliary output Cannot be used *Symbols K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 66 (Black) Control output 1 (OSSD 1) (White) Control output 2 (OSSD 2) Gray cable (with black line) (Pale blue) Output polarity setting / Lockout release input (Blue) 0V Interlock function Invalid (auto reset) External device monitor function Invalid Auxiliary output Cannot be used *Symbols K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 67: Wiring For Manual Reset (Interlock Is Valid)

    Not possible *Symbols Switch S1 Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note 1), Open: Emission K1, K2: Safety relay unit, etc. Notes: 1) Vs is the supply voltage. 2) For information on reset, refer to “3-2 Interlock Function (8-core cable, 12-core cable)”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 68 External device monitor function Invalid Auxiliary output Not possible *Symbols Switch S1 0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission K1, K2: Safety relay unit, etc. Note: For information on reset, refer to “3-2 Interlock Function (8-core cable, 12-core cable)”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 69: Wiring For Series Connection

    Not possible *Symbols Switch S1 Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note 1), Open: Emission K1, K2: Safety relay unit, etc. Notes: 1) Vs is the supply voltage. 2) For information on reset, refer to “3-2 Interlock Function (8-core cable, 12-core cable)”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 70 External device monitor function Invalid Auxiliary output Not possible *Symbols Switch S1 0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission K1, K2: Safety relay unit, etc. Note: For information on reset, refer to “3-2 Interlock Function (8-core cable, 12-core cable)”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 71: Wiring Configuration For Valid External Device Monitor Function

    (with black line) (Pale blue) Output polarity setting / Lockout release input (Blue) 0V Interlock function Invalid (auto reset) External device monitor function Valid Auxiliary output Can be used *Symbols K1, K2: External device (forcible guide relay or magnetic contactor) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 72 (Pale purple) External device monitor input K1 K2 (Blue) 0V Interlock function Invalid (auto reset) External device monitor function Valid Auxiliary output Can be used *Symbols K1, K2: External device (forcible guide relay or magnetic contactor) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 73: Wiring Configuration For Valid Muting Function

    External device monitor function Invalid Auxiliary output 1 Not possible *Symbols Switch S1 ● Test / Reset input Vs to Vs − 2.5V (sink current 5mA or less): Emission (Note), Open: Emission halt Switch S2 ● Muting input A / B, Override input Vs to Vs − 2.5V (sink current 5mA or less): Valid (Note), Open: Invalid K1, K2: Safety relay unit, etc. Note: Vs is the supply voltage. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 74 Invalid (auto reset) External device monitor function Invalid Auxiliary output 1 Not possible *Symbols Switch S1 ● Test / Reset input 0 to +2.5V (source current 5mA or less): Emission, Open: Emission halt Switch S2 ● Muting input A / B, Override input 0 to +2.5V (source current 5mA or less): Valid, Open: Invalid K1, K2: Safety relay unit, etc. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 75: Adjustment

    If the upper application indicator and lower application indicator light red or are OFF, or the operation indicator and OSSD indicator light red, the beam axes are out of alignment. All beams blocked state Receiver Upper application indicator Emitter Lower application indicator Emitter: Operation indicator Receiver: OSSD indicator Normal position Normal position <Horizontal misalignment> <Vertical misalignment> © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 76 Emitter: Operation indicator Receiver: OSSD indicator Normal position Normal position <Angle deviates to left> <Angle deviates to right> <Reference> For series connection, when all the devices connected in series receive light, the upper and lower application indicators light blue and the operation indicator and OSSD indicator light green. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 77 Hexagon-socket head bolt (M5, silver) for beam adjustment CAUTION ● Do not remove the hexagon-socket head bolt (M5, silver) for beam adjustment from this product. ● If it is still difficult to rotate the emitter or receiver even after the hexagon-socket head bolt (M5, silver) for beam adjustment is loosened, loosen the hexagon-socket head bolt [M5] or hex bolt [M6] securing the no dead-space beam adjustment mounting bracket on the mounting surface. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 78 Stable light reception state: Stable light reception state: Light intensity / Level 1 Light intensity / Level 2 Stable light reception indicator Digital indicator Stable light reception state: Light intensity / Level 3 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 79: Operation Test

    “Chapter 5 Trouble- shooting” and inform your technician. <Reference> If an indicator indicates the light-received state when the test rod blocks light, make sure there are no reflective objects or scattered light in the vicinity. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 80 For details, refer to “About the Revision of the Safety Device Management Guidelines for Press Ma- chines” (Ministry of Health, Labour and Welfare Publication 930 No. 11, September 30, 2015). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 81: Indicator Operation

    Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from the side of the device. 2) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 82 Lights red Lights red Lights red green green green green Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 83 Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from the side of the device. 2) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 84 Lights red Lights red Lights red Lights red Lights red Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 85 Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from the side of the device. 2) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 86 Lights Lights Lights Lights Lights OSSD indicator green green green green Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 87 Lights Lights Lights Lights indicator green green green green green green green green Note: The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 88 Lights red Lights red Lights red green green green green Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 89 Lights Lights Lights Lights indicator green green green green green green green green Note: The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 90 Lights red Lights red Lights red Lights red Lights red Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 91 Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from the side of the device. 2) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 92 Lights green Lights green Lights red Lights red Lights red Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 93 Lights green Lights green Lights green Lights green Lights green Lights green indicator Note: The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 94 Lights green Lights green Lights red Lights red Lights red Note: The states of the upper application indicator and lower application indicator can also be checked from the side of the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 95 3) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. 4) For details on yellow blinking or lit numbers in the digital indicator, refer to “Chapter 5 Troubleshoot- ing”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 96 3) For details on yellow blinking or lit numbers in the digital indicator, refer to “Chapter 5 Troubleshoot- ing”. After removing the cause of the error, you must turn the power OFF and then ON (the device will not recover automatically). Cause of error: Control output (OSSD) short, scattered light detected, sensor failure, etc. Refer to “Chapter 5 Troubleshooting” to remove the cause of the problem. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 97 2) The light emission intensity control indicator (orange) lights orange when long mode is selected with the DIP switches. 3) For details on yellow blinking or lit numbers in the digital indicator, refer to “Chapter 5 Troubleshoot- ing”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 98 3) For details on yellow blinking or lit numbers in the digital indicator, refer to “Chapter 5 Troubleshoot- ing”. After removing the cause of the error, you must turn the power OFF and then ON (the device will not recover automatically). Cause of error: Control output (OSSD) short, scattered light detected, sensor failure, etc. Refer to “Chapter 5 Troubleshooting” to remove the cause of the problem. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 99: Chapter 3 Functions

    3-6 External Device Monitor Function (8-core cable, 12-core cable) ········· 105 3-7 Muting Function (12-core cable) ·················································· 107 3-8 Override Function (12-core cable) ··············································· 113 3-9 DIP Switch Settings ·································································· 115 3-10 Application indicator function (12-core cable) ································ 117 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 100: Self-Diagnosis Function

    ● Install the reset switch in a location that allows operation from outside the danger zone and which provides a clear view of the entire danger zone. ● When using the device with auto-reset, use a safety relay unit or other device to prevent auto- matic restart of the system after safety output shutoff. (EN 60204-1) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 101 97 to 127 10ms 12ms 12ms 14ms 14ms 128 to 144 − 12ms 12ms 14ms 14ms 145 to 192 − 14ms 14ms 16ms 16ms 193 to 256 − 16ms 16ms 18ms 18ms © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 102: Lockout Release Function

    (Pale blue) (Blue) (Blue) *Switch S1 *Switch S2 ● Output polarity setting / Lockout release input ● Output polarity setting / Lockout release input 0 to +2.5V (source current 5mA or less): Vs to Vs − 2.5V (sink current 5mA or less): Short circuit Short circuit (Note) Note: Vs is the supply voltage. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 103: Test Input Function

    Note: The range depends on the number of beam channels and number of series connections. WARNING Do not use the test input function for the purpose of stopping the machine for which the device is installed. Risk of death or serious injury. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 104: Auxiliary Output (Non-Safety Output)

    1 / 2 negative logic) WARNING Do not use the auxiliary output for the purpose of stopping the machine for which the device is in- stalled. Risk of death or serious injury. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 105: External Device Monitor Function

    Connect the external device monitor input wire (pale purple) to the auxiliary output wire (red). Set the auxiliary output to [negative logic of control output (OSSD 1 / 2)]. When the external device monitor function is invalid, external devices cannot be connected to the auxiliary output. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 106 97 to 127 10ms 12ms 12ms 14ms 14ms 128 to 144 − 12ms 12ms 14ms 14ms 145 to 192 − 14ms 14ms 16ms 16ms 193 to 256 − 16ms 16ms 18ms 18ms © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 107: Muting Function

    If a muting sensor other than the above is used, the muting function may activate at a time not in- tended by the machine designer and create a risk of death or serious injury. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 108 Muting sensor B Muting sensor D Muting input A Muting input B <NPN output type> Muting sensor A Muting sensor C Muting sensor B Muting sensor D Muting input A Muting input B © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 109 ● Install a light shielding plate. ● Set the muting sensor and the light curtain that causes interference in a staggered arrangement. ● Lower the sensitivity of the light sensor affected by interference. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 110 L × tan5° = L × 0.0874m or more Note that nearby photoelectric sensors can cause light interference in some cases. Please check the surrounding area to see if there are sources of light interference. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 111 Machine state Bottom dead point Rise operation Top dead point Start of descent Descent operation Safety function valid Safety function invalid Safety function valid Device state (normal operation) (muting function valid) (normal operation) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 112 Muting sensor Muting state 0.08 sec. or less 0.1 sec. or less 0.14 sec. or less 0.16 sec. or less Muting auxiliary output Light received Light received state Light blocked Control output (OSSD 1 / 2) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 113: Override Function

    ● The override input is shorted to 0V or +V, and the test / reset input is open. (Continuously for 3 seconds) The override function is invalid if at least one of the two conditions is not satisfied, or if 60 sec. elapses. Note: The override function only operates when auto reset is selected (interlock invalid). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 114 When the muting indicator diagnosis function is invalid, the muting function is valid 3 sec. after the input conditions of muting sensors A (C) and B (D) are satisfied. 2) The range depends on the number of beam channels and number of series connections. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 115: Dip Switch Settings

    Turns OFF the indicators re- Power save mode Normal mode Power save duce power consumption. (Upper application indicator and lower mode application indicator, Digital indicator / received light intensity are always OFF) • DIP switch 4: ON CAUTION Make sure that the power is OFF when setting DIP switch 1 / 2 (emitter / receiver) and DIP switch 3 (emitter). If DIP switch settings are changed while the power is ON, the settings will not be re- flected. The settings will be reflected after the power is turned OFF and then turned back ON. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 116 Indicators on receiver side Upper application indicator Upper application indicator (Blue / Red / Green / Orange) (Blue / Red / Green / Orange) Lower application indicator Lower application indicator (Blue / Red / Green / Orange) (Blue / Red / Green / Orange) Light emission inten- sity control indicator (Orange) Frequency indicator Frequency (Orange) indicator (Orange) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 117: Application Indicator Function

    ● Application indicator input 1 / 2 ● Application indicator input 1 / 2 Vs to Vs − 2.5V (sink current 5mA or less): 0 to +2.5V (source current 5mA or less): Short circuit (Note) Short circuit Note: Vs is the supply voltage. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 118 Orange Synchronization + Gray / Black Application indicator input 2 Brown Auxiliary output 1 Black Control output 1 (OSSD 1) Pale blue Output polarity setting / Lockout release input White Control output 2 (OSSD 2) Blue Pale blue Output polarity setting / Lockout release input Orange Synchronization + Blue Orange / Black Synchronization - © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 119 (Gray / Black) (Gray / Black) (Blue) (Blue) Application indicator / Lights orange <Using PNP output> <Using NPN output> <Application indicator> (Brown) (Brown) (Gray) (Gray) (Gray / Black) (Gray / Black) (Blue) (Blue) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 120 Functions (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 121: Chapter 4 Maintenance

    Chapter 4 Maintenance 4-1 Daily Inspection ······································································· 122 4-2 Periodic Inspection (Every Six Months) ········································· 123 4-3 Inspection after Maintenance ······················································ 124 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 122: Daily Inspection

    Dangerous parts remain stopped as long as the test rod is present in the sensing area. □ Dangerous parts stop immediately when the power of the device is turned OFF. Be sure to test operation before using the muting function. Check the condition of the muting indi- □ cator (dirt, brightness, etc.). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 123: Periodic Inspection (Every Six Months)

    The current number of operation cycles (time) of parts with a limited service life is less than the □ number of service life cycles (time). □ No screws or connectors related to the device are loose. □ No objects that scatter or reflect light have been added near the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 124: Inspection After Maintenance

    5) When the wiring method or wiring layout is changed. 6) When a safety relay unit or external device (forcible guide relay or magnetic contactor) part has been replaced. 7) When safety controller or safety PLC settings are changed. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 125: Chapter 5 Troubleshooting

    Chapter 5 Troubleshooting 5-1 Emitter Troubleshooting ····························································· 126 5-2 Receiver Troubleshooting ·························································· 129 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 126: Emitter Troubleshooting

    (Turns OFF or blinking yellow number) Operation indicator Frequency indicator <All indicators are turns OFF> Cause Remedy Make sure the power supply capacity is sufficient. Power is not supplied. Connect the power supply correctly. Supply voltage is outside the specified range. Set the supply voltage correctly. Connector not connected securely. Connect the connector firmly. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 127 / output wire. Use the muting auxiliary output at a current from 250mA or less. Excessive rush current in the [“ ” blinks] Muting auxiliary output error muting auxiliary output. Output circuit damage. Output circuit error. Replace the device. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 128 Manual reset was selected with the test / reset input wire Open the test / reset input wire (pink). (pink) connected to 0V or +V. Take action as indicated in the troubleshooting for the emitter and receiver. If the problem per- sists, contact our office. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 129: Receiver Troubleshooting

    Digital indicator (Turns OFF or lights yellow) (Turns OFF or blinking yellow number) OSSD indicator Frequency indicator (Turns OFF or lights red) <All indicators are turns OFF> Cause Remedy Make sure the power supply capacity is sufficient. Power is not supplied. Connect the power supply correctly. Supply voltage is outside the specified range. Set the supply voltage correctly. Connector not firmly connected. Connect the connector firmly. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 130 If light emitted from a different model No. is re- [“ ” blinks] or light emitted from a differ- Scattered light error. ceived, follow the instructions in “2-3-4-3 Pre- ent model No. is received. venting Mutual Interference by Device Place- ment”. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 131 (pale purple). ternal device (pale purple) are monitor func- not connected. tion is invalid. Auxiliary output does Check if the auxiliary output wire (red) is broken or not operate correctly. has shorted. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 132 → Short to 0V or +V → Open]. The control output (OSSD 1 / 2) has been turned OFF by If the interlock function is not needed (When auto interlock. reset is used), open the interlock setting input wire (pale purple), and isolate. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 133 - wire (orange / black). (orange / black) has shorted or is broken. Take action as indicated in the troubleshooting for the emitter and receiver. If the problem per- sists, contact our office. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 134 Troubleshooting (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 135: Chapter 6 Specifications And Dimensions

    6-3-10-3 Beam Adjustment Mounting Bracket MS-SFD-1-8 ······· 159 6-3-10-4 Intermediate Support Bracket MS-SFB-2 ·················· 160 6-3-10-5 No Dead-Space Beam Adjustment Mounting Bracket MS-SFD-3-6 ·· 161 6-3-10-6 SF4B-G Compatible Mounting Bracket MS-SFD-4BG · 162 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 136: Specifications

    245 years 217 years Weight Approx. 1,900g Approx. 2,300g Approx. 2,800g Approx. 3,200g (emitter / receiver total) : Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure (in years). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 137 293 years 272 years Weight Approx. 3,600g Approx. 4,000g Approx. 4,400g Approx. 4,800g (emitter / receiver total) : Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure (in years). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 138 458 years 428 years Weight Approx. 3,600g Approx. 4,000g Approx. 4,400g Approx. 4,800g (emitter / receiver total) : Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure (in years). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 139 10 to 55Hz, 0.75mm double amplitude for two hours each in X, Y, and Z directions Vibration resistance Malfunction resistance 10 to 55Hz, 0.75mm double amplitude 20 times each in X, Y, and Z directions © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 140 10.5m or less 100mA 25.5m or less 200mA 25.5m or less 20.5m or less 350mA 25.5m or less 10.5m or less Power cable: A bottom cap cable (option) combined with an extension cable (option) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 141 Both emitter and receiver are adjusted before shipment, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Un- der the model represents the serial No.) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 142: Options

    Use to extend a 8-core cable. SFD-CC3 8-core For emitter: Gray connector SFD-CC10 For receiver: Black connector SFD-CC3-MU Use to extend a 12-core cable. 12-core SFD-CC7-MU For emitter: Gray connector For receiver: Black connector SFD-CC10-MU © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 143 ● Protective tube: Refer to the table below WARNING When using as a safety device for a press machine or paper shearing machine in Japan, always attach the protective tube SFPD-A10 (option) to the cable. (13mm) (Inner diameter ø9mm) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 144 No need to change the mounting hole pitch. Use when installing the device in a location subject to vibration. MS-SFD-4BG M5 hexagon-socket head bolt: 2 used M8 hexagon-socket head bolt: 1 used Material: SPCC © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 145 0.8 to 11m FC-SFDH-72 − SF4D-H72-01 SF4D-A36-01 FC-SFDH-80 − SF4D-H80-01 SF4D-A40-01 Material: Polycarbonate FC-SFDH-88 − SF4D-H88-01 SF4D-A44-01 FC-SFDH-96 SF4D-H96-01 SF4D-A48-01 − Note: Avoid using this cover in a place where severe vibration occurs. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 146 SF-C21 Various types of safety circuit can be configured by selecting a logic and connecting a safety device. ● Beam axis adjuster: 1 pc. Model No. Remarks SF-LAT-2N Convenient for beam adjustment. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 147 Conversion module that lets you connect a PC to the device to change function settings and monitor the device status. SF4D-TM1 The Configurator Light Curtain software is required to use the SF4D-TM1. The Configurator Light Curtain software can be downloaded free-of-charge from our website (panasonic.net/ id/pidsx/global). © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 148: Dimensions

    1,430 1,470 1,479 1,486 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,630 1,639 1,646 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,790 1,799 1,806 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,950 1,959 1,966 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 149: Side Mounting With Ms-Sfd-1-5 And Ms-Sfb-2

    1,430 1,470 1,479 1,486 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,630 1,639 1,646 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,790 1,799 1,806 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,950 1,959 1,966 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 150: Rear Mounting With Ms-Sfd-1-6 And Ms-Sfb-2

    SF4D-H72-01 SF4D-A36-01 1,420 1,400 1,430 1,474 1,488 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,634 1,648 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,794 1,808 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,954 1,968 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 151: Side Mounting With Ms-Sfd-1-6 And Ms-Sfb-2

    SF4D-H72-01 SF4D-A36-01 1,420 1,400 1,430 1,474 1,488 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,634 1,648 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,794 1,808 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,954 1,968 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 152: Rear Mounting With Ms-Sfd-1-8 And Ms-Sfb-2

    SF4D-H72-01 SF4D-A36-01 1,420 1,400 1,430 1,479 1,495 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,639 1,655 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,799 1,815 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,959 1,975 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 153: Side Mounting With Ms-Sfd-1-8 And Ms-Sfb-2

    SF4D-H72-01 SF4D-A36-01 1,420 1,400 1,430 1,479 1,495 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,639 1,655 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,799 1,815 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,959 1,975 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 154: Mounting With Ms-Sfd-3-6

    1,080 1,110 SF4D-F127-01 SF4D-H64-01 SF4D-A32-01 1,260 1,240 1,270 SF4D-H72-01 SF4D-A36-01 1,420 1,400 1,430 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 155: Rear Mounting With Ms-Sfd-4Bg And Ms-Sfb-2

    1,430 1,479 1,513 1,534 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,639 1,673 1,694 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,799 1,833 1,854 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,959 1,993 2,014 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 156: Side Mounting With Ms-Sfd-4Bg And Ms-Sfb-2

    1,430 1,479 1,513 1,534 SF4D-H80-01 SF4D-A40-01 1,580 1,560 1,590 1,639 1,673 1,694 SF4D-H88-01 SF4D-A44-01 1,740 1,720 1,750 1,799 1,833 1,854 SF4D-H96-01 SF4D-A48-01 1,900 1,880 1,910 1,959 1,993 2,014 Type SF4D-F□-01 SF4D-H□-01 SF4D-A□-01 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 157: Mounting Brackets

    6-3-10-1 Beam Adjustment Mounting Bracket MS-SFD-1-5 (Units: mm) (3.6) t 3.2 View of arrow A Ultra low-head hex socket bolt [M5 (length 5mm), opposing faces 3mm] View of arrow A Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] 45° 45° Material: SPCC © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 158: Beam Adjustment Mounting Bracket Ms-Sfd-1-6

    6-3-10-2 Beam Adjustment Mounting Bracket MS-SFD-1-6 (Units: mm) (3.6) t 3.2 View of arrow A Ultra low-head hex socket bolt [M5 (length 5mm), opposing faces 3mm] View of arrow A Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] 45° 45° Material: SPCC © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 159: Beam Adjustment Mounting Bracket Ms-Sfd-1-8

    6-3-10-3 Beam Adjustment Mounting Bracket MS-SFD-1-8 (Units: mm) (3.6) t 3.2 View of arrow A Ultra low-head hex socket bolt [M5 (length 5mm), opposing faces 3mm] View of arrow A Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] 45° 45° Material: SPCC © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 160: Intermediate Support Bracket Ms-Sfb-2

    Dimensions 6-3-10-4 Intermediate Support Bracket MS-SFB-2 (Units: mm) 22.2 M4 [(length 12), 4-R2.8 opposing faces 3mm] R21.4 30° 4-R2.8 Material: Die-cast zinc alloy © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 161: Ms-Sfd-3-6

    (Units: mm) Hex socket bolt [M5 (length 18mm), opposing faces 4mm] Hex socket bolt [M5 (length 28mm), opposing faces 4mm] View of arrow A View of arrow A View of arrow A Material: Die-cast zinc alloy © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 162: Sf4B-G Compatible Mounting Bracket Ms-Sfd-4Bg

    6-3-10-6 SF4B-G Compatible Mounting Bracket MS-SFD-4BG (Units: mm) (3.6) t 3.2 View of arrow A Ultra low-head hex socket bolt [M5 (length 5mm), opposing faces 3mm] View of arrow A Hexagon-socket head bolt with washer [M4 (length 8mm), opposing faces 3mm] 45° 45° Material: SPCC © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 163: Chapter 7 Other Information

    Chapter 7 Other Information 7-1 Glossary················································································· 164 7-2 CE Marking Declaration of Conformity ·········································· 166 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 164: Glossary

    Test rod The size of the rod is equivalent to the minimum sensing object. One of the safety states of the device. Operation stops when the self-diagnosis function determines that an irrecoverable failure (OS- SDs not operating normally, etc.) has occurred. When the emitter is Lockout in the lockout state, the OSSD and SSD of the receiver turn OFF. When the receiver is in the lockout state, the OSSD and SSD turn OFF. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 165 Abbreviation for Presence Sensing Device Initiation. This is a safety device that restarts the device automatically with- PSDI out operator intervention after the device has detected danger and temporarily halted. © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 166: Ce Marking Declaration Of Conformity

    CE Marking Declaration of Conformity 7-2 CE Marking Declaration of Conformity Itemized Essentials of EC Declaration of Conformity Manufacturer’s Name: Panasonic Industrial Devices SUNX Co., Ltd Manufacturer’s Address: 2431-1, Ushiyama-cho, Kasugai, Aichi 486-0901, Japan EC Representative’s Name: Panasonic Marketing Europe GmbH Panasonic Testing Center EC Representative’s Address: Winsbergring 15, 22525 Hamburg,Germany...
  • Page 167 Revision history First edition November 30, 2016 Second edition March 31, 2017 Third edition June 30, 2017 Fourth edition January 20, 2020 © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 168 (MEMO) © Panasonic Industrial Devices SUNX Co., Ltd. 2020...
  • Page 169 3. DISCLAIMERS (1) Panasonic Industrial Devices SUNX’s sole obligation and liability under this warranty is limited to the repair or re- placement, or refund of the purchase price, of a defective Product, at Panasonic Industrial Devices SUNX’s option.
  • Page 170 Please contact ..Panasonic Industrial Devices SUNX Co., Ltd. https://panasonic.net/id/pidsx/global Please visit our website for inquiries and about our sales network. © Panasonic Industrial Devices SUNX Co., Ltd. 2020 January, 2020 PRINTED IN JAPAN WUME-SF4D01-4...

This manual is also suitable for:

Sf4d-01 series

Table of Contents