Health O Meter 2500CKL User Instructions

Health O Meter 2500CKL User Instructions

Digital wheelchair ramp scale
Hide thumbs Also See for 2500CKL:

Advertisement

Quick Links

2500KL / 2500CKL
2500KG / 2500CKG
Digital Wheelchair Scales
Equipped with
Everlock™
User Instructions
E112697
PELSTAR, LLC
th
9500 West 55
St. McCook, IL 60525-7110 USA
www.homscales.com
© Pelstar, LLC 2018
P/N UM2500KL_2500CKL_2500KG_2500CKG_E_REV20180717

Advertisement

Table of Contents
loading

Summary of Contents for Health O Meter 2500CKL

  • Page 1 2500KL / 2500CKL 2500KG / 2500CKG Digital Wheelchair Scales Equipped with Everlock™ User Instructions E112697 PELSTAR, LLC 9500 West 55 St. McCook, IL 60525-7110 USA www.homscales.com © Pelstar, LLC 2018 P/N UM2500KL_2500CKL_2500KG_2500CKG_E_REV20180717...
  • Page 2: Table Of Contents

    2500KL / 2500CKL / 2500KG / 2500CKG Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training. TABLE OF CONTENTS Caution and Warning....................3 Specifications ......................4 Certifications / Connectivity / Disposal ..............
  • Page 3: Caution And Warning

    This product was designed to weigh patients who are safely seated in a wheelchair, seated in the 2500CKL / 2500CKG chair attachment or standing on the platform. Do not modify the product or use it for anything other than its intended purpose.
  • Page 4: Specifications

    This scale uses motion-sensing weighing technology in order to determine the actual weight of a moving patient. The 2500KL/2500CKL displays weight in pounds (lb) or kilograms (kg). Refer to Page 11 to learn more about configuring the weight measuring unit setting. The 2500KG/2500CKG displays weight in kilograms only.
  • Page 5: Certifications / Connectivity / Disposal

    Bluetooth wireless technology. This connectivity helps minimize a source of potential medical errors caused by incorrectly copying and then recording patient data. For more information regarding how to connect the scale to other electronic devices, please contact Health o meter® Professional Scales Technical Support, available during normal business hours at 1-800-638- 3722.
  • Page 6: Assembly Instructions

    Each scale is shipped disassembled in a single carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package.
  • Page 7 ASSEMBLY INSTRUCTIONS (CONT.) ® Health o meter Professional Scales recommends that assembly be performed by two people. Warning: Do not drop scale, as this can permanently damage the load cells. Caution: Do not insert the batteries into the display head until it is mounted onto the scale.
  • Page 8 Ensure that the feet are not completely tightened into the platform. *** If you are assembling this scale as a 2500CKL (with seat attachment option) stop here and for the remaining instructions see the CHAIRACC manual included in the seat assembly carton.
  • Page 9 ASSEMBLY INSTRUCTIONS (CONT.) Ramp Assembly Instructions Follow these instructions for moving the ramp to the opposite side of the scale, or for adding a second ramp to the scale (B2500RAMP option): 1. On the side of the platform opposite to the ramp, remove the guardrail mounted to the end of the platform by unscrewing and then removing the four guardrail...
  • Page 10: Powering The Scale

    AC adapter into the power source. Warning: To avoid a safety hazard, do not use an unspecified AC adapter. Only use the Health o meter® Professional AC adapter model ADPT30 designed for this scale. Power Adapter Jack For battery operation, see Battery Installation below.
  • Page 11: Set-Up Instructions

    SET-UP INSTRUCTIONS The scale must be powered on before performing any of the following operations. Press to turn on the scale. Unit of Measure Configuration / Unit Lock (This feature is not available on KG models) Unit The weight measuring unit (pounds/LB or kilograms/KG) can be changed by pressing Follow this procedure to lock the weight measuring unit into LB or KG only.
  • Page 12 SET-UP INSTRUCTIONS (CONT.) Setting Sound Options The display can be set to stay silent or beep while operating the scale. Follow this procedure to set the preferred option. Help 1. Press to access the Help menu options. 2. While in the Help menu, press to select “Set Options”.
  • Page 13 After each use, the scale will clear the weight of the patient and set itself back to the initial ZERO ® level it found on start-up. Health o meter Professional recommends keeping this setting as Enable. Note: Hitting a key to wake the scale from sleep mode will not prompt the scale to zero.
  • Page 14: Everlock™ Instructions

    Warning: This lock is permanent and can only be reversed at the factory. If you need to change the units on your scale after Everlock™ has been engaged, contact ® Health o meter Professional Scales Customer Service at 1-800-815-6615. Help 1.
  • Page 15: Operating Instructions

    OPERATING INSTRUCTIONS and selecting “Key Definitions” in the Key definitions can also be found by pressing Help submenu. Keypad Function Description Powers scale on and off. Zeroes the scale prior to a weighing. Also used as a screen navigation key to exit a Zero/ display menu.
  • Page 16 OPERATING INSTRUCTIONS (CONT.) Tare Function When using this scale, the weight of an object, such as a wheelchair, can be subtracted from the total weight in order to determine the weight of the patient alone. The Tare Function automatically performs this subtraction. The scale allows a tared weight to be entered manually by using the keypad, or automatically, as outlined in this section.
  • Page 17 OPERATING INSTRUCTIONS (CONT.) Weighing a Patient and Taring a Known Weight / Pre-Tare Pre-Tare can be performed within the following weight limits: 0.2 lb - 200 lb / 0.1 kg – 91 kg) 1. Wait until “0.0” appears on the display. Tare 2.
  • Page 18 OPERATING INSTRUCTIONS (CONT.) Weighing a Patient Standing on the Platform 1. Make sure there is nothing on the weighing platform and the display shows “0.0”. 2. Ask the patient to step on the scale. The scale will begin to display the patient’s weight and the word “PROCESSING”. Depending on the movement of the patient on the scale, it may take several seconds for the scale to lock onto the weight.
  • Page 19 6. Press to return to the normal weighing mode. (Clear) Weighing a Seated Patient on a 2500CKL Chair Attachment 1. Make sure there is nothing on the weighing platform and the display shows “0.0”. 2. Fold the seat attachment down into the open position. Assist the patient onto the seat.
  • Page 20 OPERATING INSTRUCTIONS (CONT.) Parent/Child Function ® The Parent/Child function on Health o meter Professional scales provides the convenience of weighing a small child or infant while being held by a parent. Follow these simple steps to subtract the parent’s weight from the total so only the child’s weight is displayed.
  • Page 21: Maintenance And Cleaning

    Caution: Disconnect the scale from the AC adapter power source prior to cleaning the unit. ® 1. Health o meter Professional recommends using one of the following solutions on a soft cloth or disposable wipe: ● mild soap and water solution ●...
  • Page 22: Calibration

    CALIBRATION This scale has been factory calibrated, and does not require calibration prior to use. Calibration of your scale can be performed using calibrated kilogram (kg) or pound (lb) weight standards. Minimum calibration is 200 lb / 100 kg. Maximum calibration weight is 1000 lb / 454 kg.
  • Page 23 CALIBRATION (CONT.) 7. When the zeroing process is complete the display will prompt for entry of the calibration weight. Minimum calibration is 200 lb / 100 kg. Maximum calibration weight is 1000 lb / 454 kg. Calibration weight can be adjusted in 10 lb or 10 kg increments.
  • Page 24: Troubleshooting

    TROUBLESHOOTING Troubleshooting Before contacting service personnel, refer to the following instructions to check and to ® correct any failures. For further assistance, contact Health o meter Professional Scales Technical Support at 1-800-638-3722. Symptom Possible Cause Corrective Action 1. Dead battery 1.
  • Page 25: Warranty

    What does the Warranty Cover? These Health o meter® Professional scales are warranted from date of purchase against defects of materials or in workmanship for a period of two (2) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar, LLC (see “To Get Warranty Service”, below, for instructions).

This manual is also suitable for:

2500kl2500kg2500ckg

Table of Contents