6.2.4 Precautions on Sending Data
Procedures when the end code is not added in the sending process
When you do not wish to add the terminator (end code) in the sending process, use a
negative value for specifying the No. of sent bytes.
R0
X8
DF
(
)
General-purpose
communication
R100
Clear to send flag
R100
DF
(
)
R100
DF
(
)
R100
Y8
DF /
(
)
KEY POINTS
When you do not wish to add the terminator (end code), use a negative
value for specifying the No. of sent data in GPSEND instruction. Select "SS"
for operation unit.
Y8
General-purpose
communication
Sending active flag
SSET
NEG.SS
UNITSEL
GPSEND . SS
DT101
R101
"ABCDE"
DT100
S1
S2
DT100
DT100
S1
D
U0
U1
S1
S2
DT100
DT0
S
n
D
6.2 Sending Operation
R100
GPSEND execution conditions
Clear to send flag: ON
Sending active flag: OFF
Data conversion
S1: Sent Data
S2: Save Sent Data
DT100: No. of Sent Characters
DT101 onward: Sent Data
Because no end code is added,
use a negative value for
specifying the No. of sent bytes.
Settings for communication port
S1: Slot 0 (U0)
S2: COM1 (U1)
SEND processing
S: Header of Sent Data (DT101)
n: No. of Sent Characters (DT100)
D: Execution Result Code (DT0)
R101
Confirm sending completion
Reset GPSEND execution
conditions
6-7