  • Page 1 (217) 352-9330 | Click HERE Find the Hitachi KP-M1E/K at our website:...
  • Page 2 KP-M1A B/W CCD Camera Operation Guide Aug 2001 KP-M1A - 1 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3: Table Of Contents

      Table of contents General ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3 Major features ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3 Specifications ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4 Name of each section ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 Signal connection to DC IN/SYNC connector ・・・・・・・・・・・・・・・ 7 Arrangement of internal switches ・・・・・・・・・・・・・・・・・・・・・・・・・ 8 External synchronization ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 10 Field on demand function・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 11 Timing chart ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・...
  • Page 4: General

    1. General The KP-M1A is a black and white camera using the latest high grade CCD having a 2/3-inch image size. The KP-M1A features high sensitivity, high resolution and high performance. The KP-M1A is provided with various functions including the multiple step electronic shutter function, field-on-demand function, integration mode switching function, HD/VD pulse switching function and non-interlaced scanning function.
  • Page 5: Specifications

    3. Specifications (1) Imaging device interline CCD EIA :811(H) ×508(V) No. of total pixels CCIR:795(H)×596(V) Pixel size EIA :11.64(H)×13.5(V)µm CCIR:11.6(H)×11.2(V)µm No. of effective pixels EIA :768(H)×494(V) CCIR:752(H)×582(V) EIA :8.94 ×6.67mm(2/3 inch size) (2) Sensing area CCIR:8.72 ×6.52mm(2/3 inch size) (3) TV format EIA/CCIR (4) Lens mount C-mount...
  • Page 6 (17) Integration mode Field or frame (Settable by external switch.) Set to frame integration mode at factory. (18) Gamma correction Gamma = 1.0 or correction (Settable by internal switch.) Set to 1.0 at factory. (19) AGC Fixed or AGC (Settable by internal switch.) Set to fixed gain at factory.
  • Page 7: Name Of Each Section

    4. Name of each section (1) VIDEO OUT (BNC) connector A composite video signal (VS) is fed from this connector. Connect a 75-ohm coaxial cable between the connector and a video monitor or other video equipment. (2) Shutter speed select switch Use this switch to set the shutter speed.
  • Page 8: Signal Connection To Dc In/Sync Connector

    5. Signal connection to DC IN/SYNC connector. External sync mode Internal sync Frame/field on demand mode HD/VD ONE trigger Fixed shutter TWO trigger EXT shutter +12V +12V +12V +12V +12V +12V GND(Vout) GND(Vout) GND(Vout) GND(Vout) GND(Vout) GND(Vout) Vout Vout Vout Vout Vout Vout...
  • Page 9: Arrangement Of Internal Switches

    6. Arrangement of internal switches Internal controls Gamma characteristic GAIN(RV301) select switch Factory setting position REAR side LENS side OFF(gamma=1.0)    ON(gamma=0.45) Gain select switch SET UP(RV304) Factory setting position W.CLIP(RV303) W.SUP(RV302) Normal gain           AGC KP-M1A - 8 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10 Gain control Adjusts a video level. Set to 0.7Vp-p at 400lx, f4. (Gamma: off, AGC: Normal) SET UP control Adjusts a setup level. Set to 75 mVp-p. (Gamma: OFF, AGC: Normal) W.CLIP control Clips a video level. Set to 1.0Vp-p. (Max: 1.2Vp-p) W.SUP control Prevents white compression of a video signal and extends a dynamic range.
  • Page 11: External Synchronization

    7. External synchronization (2:1 interlaced) When operating the camera by external drives signals, connect sync drive signals (HD, VD) to the DC IN/SYNC connector, then the mode is automatically switched from the internal sync mode to the external sync mode. Horizontal and vertical drive signal inputs EIA: f(H) = 15.734 kHz ±1 % CCIR: f(H) = 15.625 kHz ±1 %...
  • Page 12: Field On Demand Function

    8. Field on demand function The KP-M1A is provided with the Field-on-Demand function to record a picture obtained at an optional timing by triggering to an image memory, etc. Four modes are switchable by the internal switch. 1) ONE trigger mode 2) TWO trigger mode 3) Fixed shutter mode: 1/1600s(EIA) / 1/1000s (CCIR) 4) External shutter control mode...
  • Page 13 (2) Difference between the restart/reset (R/R) function and the Field-on-Demand (FD) function. R.R. A: Image required for the pulse Restart sync signal only A: Image required for the (Fixed shutter) pulse Reset sync signal and start of shutter R/R function: The desired image is after one field with respect to the input pulse. FD function: The desired image is immediately after the input pulse.
  • Page 14 (3) Timing diagram KP-M1A - 13 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 15 8-1 ONE trigger mode The shutter is started by the rising edge of the trigger A pulse, and V.SYNC is reset by the falling edge of the trigger A pulse. (After reset, the first field is delivered) A shutter time is controlled by the duration when the trigger pulse is high. Only one field image is delivered by one trigger pulse, and a sync signal lasts till the next pulse.
  • Page 16 8-2 TWO trigger mode V.SYNC is reset by the falling edge of the trigger A pulse. (After reset, the first field is delivered.) The shutter is started by the rising edge of the trigger B pulse. The trigger B pulse is inhibited from the falling edge of the trigger A pulse to 9 to 12H(EIA) /14 to 17H(CCIR), and a correct picture is not obtained.
  • Page 17 8-3 Fixed shutter mode: 1/1600s(EIA), 1/1000s(CCIR) The shutter is started by the falling edge of the trigger A pulse, and at the same time V.SYNC is reset. (After reset, the first field is delivered.) In this mode, the shutter speed is fixed to 1/1600s (EIA) / 1/1000s(CCIR). Only one field is delivered by one trigger pulse, and a sync signal lasts till the next pulse.
  • Page 18 8-4 External shutter control mode The shutter is started by the rising edge of the trigger B pulse. The shutter is effective only for the next field of the pulse input. When the trigger B pulse is not supplied the normal exposure results. The V.SYNC pulse of the camera is not reset.
  • Page 19: Timing Chart

    9. Timing chart   KP-M1A - 18 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20   KP-M1A - 19 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21   KP-M1A - 20 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22    KP-M1A - 21 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23     KP-M1A - 22 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24   KP-M1A - 23 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25: Electronic Shutter

    10. Electronic shutter Shutter speed select switch Set the SHUTTER ON/OFF switch to ON, then set the speed with the shutter speed select switch. SHUTTER ON/OFF switch Setting of shutter speed Setting Speed Relative Setting Speed Relative position (second) sensitivity position (second) sensitivity...
  • Page 26: Connection

    11. Connection Connection of options KP-M1A Coaxial cable Image processor Connect either of the cables. Video monitor Coaxial cable Camera cable JUNCTION BOX AC adaptor (Option) JU-M1A AP-130 +12V When not using the AP-130, supply 12V from the rear of the Junction box.
  • Page 27: Optical System

    12. Optical system 1 Flange focal ・  Image size: 2/3-inch ・  The flange focal distance is 17.526mm(in air). ・  Flange focal distance cannot be adjusted. Note: Select such a lens as the length (A) from the flange surface of the lens to the end of the screw side is 8mm or less.
  • Page 28: Composition

    13. Composition 1)Camera(With dummy glass, AR coated) 2)Operation manual 14. External view 15. Optional accessories 1)Tripod adapter, TA-M1 2)12-pin plug, HR10A-10P-12S(01) 3)Junction box, JU-M1A 4)Dummy glass, ARC1214 5)Camera cables Mould Type Assembly Type Shield Type C-201KSM C-201KS C-201KSS C-501KSM C-501KS C-501KSS C-102KSM C-102KS...
  • Page 29 1) Tripod adaptor TA-M1 Secure the adaptor to camera mounting holes B, using four supplied screws(M2x5). Note: If the screws are too long, they will cause trouble to the camera. Be sure to check the length before use. 2) 12-pin plug HR10A-10P-12S(01) Product code: 23810AX Viewed from this side 3) Junction box JU-M1A...
  • Page 30 4) Dummy glass ARC1214 Parts code: XMD0009 5) Camera cables Optional cables are available to connect the camera and the Junction Box JU-M1A. Length Type C-201KSM C-501KSM (BLK) C-102KSM (WHT) (RED) YEL (ORN) ・ Voltage drop due to a cable is about 0.01V per meter. ・...
  • Page 31 ・  A ttenuation of video signal due to used cable Attenuation due to optional cables C-501KSM and C-102KSM is shown below. Attenuation is proportionate to the cable length. Characteristic impedance is kept at constant even at cable length change. Cable Attenuation at 4MHz Attenuation at 7MHz length...
  • Page 32: Notes To Users

    16. Notes to users " Power supply Connect a 12V DC voltage (11 to 13V) from an external regulated DC power supply. Use a stable power supply without ripple and noise. Prior to turning on the power switch , check that the polarities of the power cable are correct , referring to the connection diagram "...
  • Page 33 " Phenomena inherent to CCD imaging device " Following are phenomena inherent to a CCD imaging device , and not defects. Smear and blooming When strong light (lamp , fluorescent lamp , reflected light , etc.) is shot , pale bands are displayed vertically above and below the light.
  • Page 34: Attachment : Spectral Sensitivity Characteristic

    Spectral sensitivity (typical example) Spectral responce characteristics        KP‑M1A        IR‑FILTER 1000 Wave length(nm) KP-M1A - 33 - Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35 , and the cost is changed to a customer. (3) Hitachi Kokusai Electronic is not liable for the losses caused when the equipment is used in a system used for business trades , production process , medical fields , crime prevention applications , etc.

This manual is also suitable for:

Kp-m1a