Interface Connector Connection (Rs-232C Connecting Part); Interface Setting (Dip Switch Operating Part) - Fujitsu 628WSL110H2 User Manual

Portable thermal printer
Table of Contents

Advertisement

9. Interface Connector Connection (RS-232C Connection Part)
1) Part No.: RL01-R12P (Japan Aviation Electronics Industry, Ltd.) or equivalent
2) Signal pin assignment
No.
Signal name
1
GND
2
RxD
3
TxD
4
DTR
5
DSR
6-12
N.C.
・Input and output are defined from the printer side.
Note)
・For pin number, refer to the figure below.
3) Connector model No.: RL01-P12S-C (Japan Aviation Electronics Industry, Ltd.) or
equivalent

10. Interface Setting (Dip Switch Operating Part)

Bit No.
1
2
3
4
Direction
---------
Input
Output
Output
Input
--------
Function
Interface setting
Communication mode
Reserve
Start
program
selection
Function
Signal ground
Receive data
Send data
Data terminal ready
Data set ready
Not connected
Setting
Description
OFF
Wireless interface
ON
Wired interface
OFF
Teletype protocol mode
ON
Packet communication mode
OFF
ON
OFF
Printer execution mode
ON
Program download mode
29 