C3.
ADAPTING BLOWER
FOR RECIRCULATION
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
Remove and save screws that hold blower plate
1
and blower unit to the oven. Remove the cover
plate installed on the back
Blower Plate Screws
Slide the blower plate from under its retaining
2
flange and lift it off.
Retaining
Flange
3
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust the
blower unit.
38
Installation Instructions
Blower Plate
Back of
Oven
Blower Motor Screw
Cover Plate
Blower
Plate
4
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the oven.
BEFORE: Fan Blade
Openings Facing Up
Roll
AFTER: Fan Blade
Openings Facing
Forward