Rfss Mode (Rf Signal Strength) - Bosch wLSN System Reference Manual

Wireless local securitynetwork
Table of Contents

Advertisement

8
en | RFSS Mode (RF Signal Strength)
3

RFSS Mode (RF Signal Strength)

CAUTION!
When testing for RF signal strength, the wLSN Diversity Hub
and the control panel must be set to the same EN50131
Security Grade.
CAUTION!
If you have wLSN devices that you will not immediately install,
reinsert the battery tabs or remove the batteries to prevent
battery depletion.
NOTICE!
Do not permanently install the wLSN Diversity Hub or any wLSN
devices until you receive acceptable, or better, signal strength
readings between the wLSN Diversity Hub and all wLSN device
locations.
If you receive unacceptable or marginal readings at several
wLSN device locations, move the wLSN Diversity Hub to a
different location and re-test for RFSS until you receive at least
acceptable readings at all wLSN device locations.
Perform a radio frequency signal strength (RFSS) test to
determine the best installation locations for the wLSN Diversity
Hub and each wLSN device.
To perform the RFSS test:
1.
2.
F01U138553 | 01 | 2010.05
Prepare the wLSN Diversity Hub for RFSS testing.
Refer to Section 3.1 Page 9.
Conduct an RFSS test using the wLSN Diversity Hub and
Installation Tool. Refer to Section 3.2 Page 10.