Built-in Household Cassette Air Conditioner
Contents
Before use
Maintenance
Indoor unit installation
Instroduction
Electric wiring
Tests and trial operation
No:0010571442
B
l Please read this operation manual carefully before using the appliance.
l Keep this manual in a safe place.
AB092FCBHA
AB142FCBHA
AB182FCBHA
**************************1-3
***************************4
*********************5-7
************************ 8
********************* 9
*********************10-12
*************************13
***********************14-16
*************************17
*****************18-21
********************** 22
***********************23
*******************24

Advertisement

Table of Contents
loading

Summary of Contents for Haier AB092FCBHA

  • Page 1: Table Of Contents

    Installation of indoor unit Pipe connection Electric wiring Tests and trial operation No:0010571442 l Please read this operation manual carefully before using the appliance. l Keep this manual in a safe place. AB092FCBHA AB142FCBHA AB182FCBHA *********************5-7 ************************ 8 ********************* 9 *********************10-12...
  • Page 2 Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 3 Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
  • Page 4 Compensation for power interruption (Applicable accordingly) If this function is set, the air conditioner will return to the original operating state after the power supply is interrupted and then resumed. Setting: When the power supply is connected and the remote control is activated...
  • Page 5: Cautions **************************1-3

    Defrosting During the heating process, the air conditioner can automatically defrost ice accumulated on the outdoor unit heat exchanger. This process takes a few minutes. When the defrosting mode is activated, the outdoor unit and indoor unit cease operation.
  • Page 6: Safety Precautions *********************5-7

    Safety precautions Interpretation of four symbols: WARNING A potentially hazardous situation*which, if not avoided, could result in serious injury or death CAUTION A potentially hazardous situation, which, if not avoided, may result in minor or moderate injury or damage to the equipment Operation so marked is not allowed, or serious damage to equipment or fatal injury to operator may result.
  • Page 7 Dismounting and reinstalling the air conditioner must be carried out by authorized after-sales agents. Improper installation may result in fire, electric hazards and water leaks.
  • Page 8 Never clean the air conditioner with water to prevent electric hazards. Never place or use inflammable spray on or close to the air conditioner to prevent fire. Avoid contact with the switch of the air conditioner when hands are wet to prevent electric shocks.
  • Page 9: Maintenance

    Maintenance Unplug the appliance Remove the air intake screen Hold the air intake screen with one hand, and push the screen inward with the other hand to release four tabs from the slots to remove the screen. Remove the filter Rotate the fixing clip 90∞.
  • Page 10: Seasonal Cessation

    Seasonal cessation Post maintenance Turn the air conditioner on during a sunny day and leave it running for about 6 hours. Turn the air conditioner off and disconnect it from the power source. Clean the filter, the indoor unit and outdoor unit before applying covers.
  • Page 11: Trouble Shooting *********************10-12

    Trouble shooting The following are not problems. Water gurgling sound Pop sound Strange odor Mists from indoor unit Automatic airflow mode set during cooling process Immediate restarting not recommended A slight sound similar to water gurgling can be produced when the appliance is turned on and off, or the compressor started or ceased during operation period of the appliance.
  • Page 12 The indoor unit does not stop after heating function is ceased Please undertake following tests before contacting authorized after sales service for technical assistance. The air conditioner does not operate Is the switch connected to the power resource? The switch is not turned on.
  • Page 13 Other heat source in the room. Should any of the following circumstances occur after inspection has been carried out for the items listed above, turn off the air conditioner and contact authorized after- sales service agent: Regular break of fuse and circuit.
  • Page 14: Precautions *************************13

    Following instructions should be strictly followed for appliance operation. l Installation must be carried out in accordance with the requirements listed hereunder. l When the air conditioner is moved, special care should be taken to avoid dents or scratches on the case surfaces.
  • Page 15 Wiring cables will be properly arranged and connected, ensuring there in no entrapment from the cabinet case or exterior sheet. When the air conditioner is relocated, make sure that air or foreign articles are prevented from entering the refrigerant (R407C) as excessive pressure might be generated, resulting in injuries or damage to the cooling circulation system.
  • Page 16 Knife 2-sided Water-proof Connection adhesive insulation hose tape material 3G(1.0-1.5)mm 2X(0.75-1.5) mm Shielded wire Copper tube option AB092FCBHA O 6.35(1/4") O 9.52(3/8") Pliers Leak tester and soap solution Steel tape Scraper and file Refrigeration oil(polyol ester) Drainage Gesso hose AB182FCBHA AB142FCBHA O 6.35(1/4")
  • Page 17 Introduction Accessories and components The following are complete accessories and components provided by the manufacture for the air conditioner installation. Code Remote Controller Figure Quantity Code Ring Rubber Pad Figure Quantity Code screw 4x20 Figure Quantity wire Binder Battery Refrigeration Oil...
  • Page 18: Procedures *************************17

    Procedures Firm and free from vibration Open and away from heat and steam sources Convenient for water drainage and connection to the heat pump Favorable for airflow spread Accessible to power source with required space around the appliance Free from TV sets, radio, cordless appliance and at least 1 meter away from the light Convenient for receiving signals from remote controller fixed on the wall with the light on...
  • Page 19: Installation Of Indoor Unit *****************18-21

    Installation of indoor unit I. Location 1. Between the ceiling and the upstairs floor. 2. Favorable for water drainage pipes 3. Less than 2.7 meters above the floor for air outlet opening 4. Open for air circulation 5. Away from the area where heavy oily dusts, moisture or steam is likely to accumulate, such as kitchens and workshops 6.
  • Page 20 Installation of indoor unit Installation of hanger rod Foundation or countersunk bolts are used on the roof to hold the indoor unit if ceilings are completed. Adjust the space between the indoor unit and ceilings. III. Installation of indoor unit Installation to the roof without ceilings Temporary installation Ensure that the hanger rods are properly set to the slot of the pedestals on the indoor unit.
  • Page 21 Installation of indoor unit IV. Installation of water drain 1. Installation of water drainpipes l Diameter of water drainpipes should exceed or be equal to that of connecting pipe. (Polyethylene pipe: inside diameter 25mm and outside diameter 32mm.) l Water drainpipe should be short with a gradient of at least 1/100. l If required gradient cannot be reached, a riser tube should be installed.
  • Page 22 Installation of indoor unit V. Installing decorative sheets 1. Verify with water level or water filled Polyethylene pipe that the indoor unit is horizontally installed and specifications of the holes on the ceilings are correct. Remove the water level before installing the decorative sheets. 2.
  • Page 23: Pipe Connection

    Pipe connection Schematic diagram for unit connection Indoor unit Flared pipe connection Indoor unit Connection pipe dimensions: Pipe Value 6.35mm Liquid 9.52mm Gaseous 9.52mm Liquid 12.7mm Gaseous l Apply and tighten the nut. 3. Maximum length and height difference of connecting pipe l Maximum length: 20m;...
  • Page 24: Wiring Of Indoor Unit

    Electric wiring Process of wire connections 1. Loop terminal After removing the screw, fix the wire ring on the screw, reinsert the screw into the block terminal and then tighten the screw. 2. Straight terminal After loosening the screw, inset the wire end into the block terminal and then tighten the screw.