Chapter 2 Convenient Features
(2) Power Control Configuration submenu
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option
AC-LINK
Power On Delay Time Mode
Delay Time
Cold Redundant Mode
70
Parameter
Stay Off
Specify AC link feature. Specify how the DC power state
should be when the AC power is supplied again after loss
[Last State]
of power. (See the table below)
Power On
[Manually Setting]
Select a method to specify the delay time before
powering on DC power. Available options are:
Random
"User-specified value" or "random value".
This option is selectable when Power On or Last State
is specified in AC-LINK.
[45]-600
Specify the delay time within the range between "xx"
and 600 seconds. The minimum configurable time is
displayed when executing Load Setup Defaults. The
minimum configurable time may differ from the factory
default value.
This menu appears when Manually Setting is specified
for Power ON Delay Time Mode.
[Disabled]
Enable or disable Cold Redundancy feature.
Enabled
Express5800/E120d-M Maintenance Guide
Descriptions
[
]: Factory settings