Port Qualifier Information
This parameter releases the Port Qualifier Information (PQI).
The PQI provides information on the port status and the IO-Link device status.
Port configuration without S7-PCT
This parameter enables the port configuration without S7-PCT for the module.
Operating mode
This parameter determines the mode in which you operate the selected port.
You can select from the following options:
• IO-Link Autostart
• IO-Link Manual
• DI
• Deactivated
The setting of the port is granular and you can combine the operating modes as you like.
IO-Link Autostart
The connected IO-Link device starts automatically (Plug&Play functionality). The IO-Link
device is immediately available to you and operational.
IO-Link Manual
If the Vendor ID and Device ID match the connected device, the connected IO-Link device is
automatically started. In other words, in contrast to "IO-Link Autostart", the system checks
here whether the correct device is connected. You need to configure the Device ID / Vendor
ID to enable this.
You need to store the Vendor ID and Device ID of the connected IO-Link device in STEP 7.
In addition, you can select the inspection level for data storage:
• Identical type (V1.0) without Backup&Restore
• Type-compatible (V1.1) without Backup&Restore
• Type-compatible (V1.1) with Backup&Restore
• Type-compatible (V1.1) with Restore
You can find instructions for determining the Vendor ID and Device ID on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/109748852).
DI
The port operates as standard digital input.
Deactivated
The port is deactivated.
Communication module IO-Link Master CM 8xIO-Link (6ES7547-1JF00-0AB0)
Equipment Manual, 08/2022, A5E45488510-AB
Parameters / address space
4.2 Declaration of parameters
21