  • Page 1 INTEGRATION AND CONFIGURATION OF HUAWEI INVERTER WITH TRYDAN...
  • Page 2: Electric Installation

    4, respectively. After that, we must establish RS485 communication by connecting pin 24 (A) and 25 (B) of the meter to pin 3 and 4 of the communications connector of the Huawei inverter respectively. The clamp should be connected according to the following scheme:...
  • Page 3: Communications Configuration

    Communications Configuration This section will show step by step how to configure the Huawei inverter to communicate with Trydan and send the measurement data to Trydan. Huawei Configuration SUN2000 Once the installation is done, we will be able to configure the communication of the Huawei inverter thanks to the Wi-Fi signal it generates.
  • Page 4 Confirm connection The current Wi-Fi connection cannot access the Internet, do you want to switch to mobile data? Maintain Use mobile data By default, the network SSID will be SUN2000-(SERIAL NUMBER) and the password is Changeme. Once connected, some devices will show a warning that the network has no internet connection. We will have to press to maintain the connection and then we will press to continue inside the SUN 2000 app.
  • Page 5 Power meter configuration To configure the meter, go to Maintenance from the home screen. Click on Manage sub-device and add our DDSU666-H (single phase) meter. The inverter will start scanning the device and if the connections are correct, it will add it automatically. If the measurements or the energy diagram shown is not logical, we must change the direction of the clamp or configure this direction in the meter options through this same app.
  • Page 6: Final Result

    Trydan will display an error message if it fails to connect to Huawei, check your connection and make sure that the two devices are connected to the same network. If the connection is correct, it will show the...
  • Page 7 Due to the recent update that Huawei has released to the SUN2000 family inverters, the communication protocol used by Trydan has been disabled. After contacting Huawei to solve this problem, they indicate that the only way to re-establish communication is by connecting an SDongleA to our inverter.
  • Page 8 I t will allow us to update the equipment to be the correct version by uploading it from our smartphone. Click on Manual Selection and look for this file which can be downloaded from the following link https://drive.google.com/file/d/1mqxrzA3c_7eEkTUueztCHdiApzA6vv51/view?usp=sharing Click on Dongle Update and wait for the process to finish following the instructions on the screen. This process should not modify the Wi-Fi configuration of the inverter, but it is advisable to check it later by entering the inverter configuration.
  • Page 9 Display RS485_1 Dongle communication channel We must consult the communication channel used by the Huawei inverter to then be incorporated into the Dynamic Power Control settings. Currently there are 3 communication channels (0, 1, 2). To do this, click on Communication Settings >> RS485_1 >> Comm Address.