O P E R A T I O N S; Preparation For Operation; Operating Procedures; Operation Of W O W Flutter Meter - Kenwood FL-180 Instruction Manual

Wow flutter meter
Table of Contents

Advertisement

Preparation for Operation

1. Set the power selector switch to the correct voltage observing the "arrow" mark
on the plug. The F L - 1 8 0 is factory set to operate on A C 2 4 0 V .
2. Set the control knobs as follows:
RANGE: 1 %
FUNCTION: W T D
INDICATION:
A s desired
L E V E L MODE, O S C : A s desired.
3. Connect the power cord to the A C outlet and press the A C switch © . The
frequency display
The F L - 1 8 0 is now ready for operation.
Note:
When the power is ON, the LED lamp ( O V E R F L O W / L E V E L MONITOR) ®
flicker and the meter deflects off the scale.
This is normal and is not an indication that the meter is defective.
R or L
R or L Play terminal
R E C
Terminal
Tapedeck

Operating Procedures:

Operation of w o w flutter meter

1. Connect the F L - 1 8 0 to the equipment to be tested, such as tape recorder or
turntable.
2. In testing tape recorder, use a w o w flutter test tape, or record and play the sig-
nal of the O S C output terminal (3) . In testing turntable, use a wow flutter test
record.
Note:
To measure w o w flutter according to J IS, N A B or CCIR standard, use a tape or
record containing 3 kHz of center frequency (3.1 5 kHz for DIN).
3. Plug an A C power cord to A C outlet. Push the pushbutton switch © , and the
4-digit frequency display
operation.

O P E R A T I O N S

@ will light to indicate " 0 0 0 0 " .
F L - 1 8 0
Fig. 4 Connecting the F L - 1 8 0
@
indicates " 0 0 0 0 " . The F L - 1 8 0 is ready for
will
R or L Channel
R e c o r d p l a y e r
11