2 Configuration and Operation
Figure 2-2: Frequency Range List Configuration
Defining a start frequency as 3.473 Ghz and an end frequency of 3.583 Ghz with a
step of 11 Mhz is similar to defining singular frequencies as 3.473 Ghz, 3.484 Ghz,
3. 495 Ghz ..., 3.583 Ghz. The CPE will scan all available frequencies in the range
and try to connect to the BS with the highest CINR.
2.2

Scan Priority and CINR Threshold

For singular frequencies with a set priority, the CPE will scan the defined
frequencies in order of priority with the lowest numeral being the highest priority.
The scanning will stop if a BS signal is found with a CINR that is above the defined
CINR threshold. The CPE will then try to connect to this BS.
The following figure illustrates the priority configuration with CINR threshold.
How to Configure the CPE Scanner