Hitachi Relion 670 Series Product Manual page 104

Phasor measurement unit
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Phasor measurement unit RES670
Version 2.2
Table 178. Station communication
Position
1
2
3
P
Table 179. Station communication functions
Function
IEC 61850-9-2 Process bus communication, 8
merging units
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
Protocol reporting via IEEE 1344 and C37.118
Protocol reporting of phasor data via IEEE 1344
and C37.118, phasors 1-8
Protocol reporting of phasor data via IEEE 1344
and C37.118, phasors 9-16
Protocol reporting of phasor data via IEEE 1344
and C37.118, phasors 17-24
Protocol reporting of phasor data via IEEE 1344
and C37.118, phasors 25-32
Protocol reporting of analog data via IEEE 1344 and
C37.118, analogs 1-8
Protocol reporting of analog data via IEEE 1344 and
C37.118, analogs 9-16
Protocol reporting of analog data via IEEE 1344 and
C37.118, analogs 17-24
Protocol reporting of binary data via IEEE 1344 and
C37.118, binary 1-8
Protocol reporting of binary data via IEEE 1344 and
C37.118, binary 9-16
Protocol reporting of binary data via IEEE 1344 and
C37.118, binary 17-24
Rapid spanning tree protocol
1)
PRP or HSR require two SFPs placed in pairs.
2)
This functionality requires accurate time synchronization, therefore either 'Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
3)
Qty of PHASORREPORT1 must be equal to the qty of PMUREPORT.
4)
Qty of PHASORREPORT2–4, ANALOGREPORT1–3 and BINARYREPORT1–3 must be equal or less than PMUREPORT.
5)
Option RSTP require 2 SFP placed in pairs.
Table 180. Language selection
Language
First local HMI user dialogue language
HMI language, English IEC
Additional local HMI user dialogue language
No additional HMI language
HMI language, English US
1)
Additional 2nd languages are continuously being added. Please get in touch with local Hitachi Power Grids sales contact.
Table 181. Casing selection
Casing
1/2 x 19" rack casing, 1 TRM
3/4 x 19" rack casing, 1 TRM
3/4 x 19" rack casing, 2 TRM
1/1 x 19" rack casing, 1 TRM
1/1 x 19" rack casing, 2 TRM
104
4
5
6
7
Function identification
PRP
HSR
PMUREPORT
PHASORREPORT1
PHASORREPORT2
PHASORREPORT3
PHASORREPORT4
ANALOGREPORT1
ANALOGREPORT2
ANALOGREPORT3
BINARYREPORT1
BINARYREPORT2
BINARYREPORT3
RSTP
© 2017 - 2022 Hitachi Energy. All rights reserved
8
9
10
11
Ordering no
1MRK005933-HC
1MRK005932-FA
1MRK005932-NA
1MRK005928-VR
1MRK005928-YB
1MRK005928-YC
1MRK005928-YD
1MRK005928-YE
1MRK005928-YF
1MRK005928-YG
1MRK005928-YH
1MRK005928-YK
1MRK005928-YL
1MRK005928-YM
1MRK005933-SA
Ordering no
1MRK002930-AA
1MRK002920-UB
Selected
Ordering no
1MRK000151-VA
1MRK000151-VB
1MRK000151-VE
1MRK000151-VC
1MRK000151-VD
Selected
1MRK 511 410-BEN P
12
13
14
15
0
Position
Available
Selected
qty
qty
1
0–1
2
0–1
3
0–1
4
1–2
5
1–2
6
0–2
7
0–2
8
0–2
9
0–2
10
0–2
11
0–2
12
0–2
13
0–2
14
0–2
18
0-1
Selection
Notes and rules
B1
X0
1)
A12
B1
Selection
Notes and rules
A
B
C
D
E
16
17
18
0
0
Notes and rules
1)
2)
3)
,
4)
5)
Hitachi Energy

Advertisement

Table of Contents
loading

This manual is also suitable for:

Res670