Mycro Configuration; Overview; Load Mycro Configuration - Bosch rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for rexroth Sytronix FcP 5020:
Table of Contents

Advertisement

FcP 5020

7.12 myCro Configuration

7.12.1 Overview

myCro is a function package based on FcP system, for controlling a hydraulic ex-
haust device by Bosch Rexroth called "myCro", which controls speed variable
pump to adjust hydraulic fluid in constant pressure for gas exhausting. myCro
swithes pump on / off for degassing automatically according to gas content
feedback.
In FcP default setting, the myCro function package is not active. This myCro spe-
cialized function can be activated by setting F1.20 = 4.

7.12.2 Load myCro Configuration

The following table shows the parameters will be mostly used for myCro func-
tion. Part of the parameters have different values in FcP default and myCro de-
fault, these will be set to myCro default by setting F1.20 = 4.
Code
Name
Pressure command selec-
F1.04
tion
F1.05...
Pressure command
F1.08
Flow command digital set-
F1.12
ting
Flow command digital set-
F1.13
ting 1
F1.14 Flow command selection
CytroPac parameter initiali-
F1.20
zation
DOK-RCON03-FCP5020****-QU04-EN-P
Block Diagram of Main Functions
Setting range
0: Pressure command digital setting
0
1: Pressure command digital setting
1
2: Pressure command digital setting
2
3: Pressure command digital setting
3
0.0...1,000.0 bar
0...5,000 rpm
0...5,000 rpm
0: Flow command digital setting 0
1: Flow command digital setting 1
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac premium
4: myCro
Bosch Rexroth AG
FcP
myCro
default
default
0
0
10.0
160.0
400
2500
400
400
0
0
0
0
57/83