Block Diagram of Main Functions

7.9.5 Pump Power Limitation

Code
Name
Pump
function
F4.03
configuration
word
F4.30 Pump Vg1
F4.31 Pump Vg2
Effective
Pump
F4.38
Vg
F4.35 Pump power
Tab. 7-18: Parameter list of pump power limitation
Pump power limitation function can be activated via bit0 of F4.03.
The real-time pump power can be calculated from pressure feedback, the actual
speed and pump displacement. If the calculated pump power output exceeds
the pump power limitation [F4.35] then the speed will be reduced to keep the
pump power output within the limit.
In pump power limitation function pump displacement "Effective Pump Vg"
(F4.38) will be used for the calculation, for application with constant pump dis-
placement F4.38 = F4.30, for application with 2 point pump or double pump,
F4.38 will be calculated with F4.30 and F4.31 according to pump switching log-
ic.
42/83
Setting range
0...63
Bit0: Pump power limit
Bit1: Pump thermal protection
Bit2: Switch master to slave
Bit3: Two points / double pump
Bit4: Pressure drop / overshoot compensation
Bit5: Activating myCro
0...1,000 ccm
0...1,000 ccm
0...1,000 ccm
0.00...315.00 kW
Default
Min.
0
-
0
1
0
1
0
1
0.00
0.01
DOK-RCON03-FCP5020****-QU04-EN-P
FcP 5020
Attri.
Stop
Stop
Stop
Read
Stop