Power And Motor Connections (Single Phase) - Bosch Rexroth EFC 3600 Easy Start Manual

Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

Easy Start Guide
Bosch Rexroth EFC 3600 Series Inverter

1. Power and Motor Connections (Single Phase)

Neutral
Notes:
The illustration above is based on the frame
size B model (0.75kW). The terminal layout for
sizes A, C and D (0.37kW, 1.5kW and 2.2kW is
similar.
The order of the three phases determines the
direction the motor turns.
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
Drive Supermarket and must not be reproduced or altered without prior written permission.
Before commencing, confirm that the Inverter and
all cables are completely isolated from the power
supply, have been isolated for at least 5 minutes
and that the motor is not turning.
Live
Earth
Power
(+)
Important:
Use screened SY cable between the Inverter
and Motor to minimise electromagnetic
interference.
Ensure the motor cable screen is earthed at
the motor end.
©
The Inverter
Phase
Phase
Phase
Earth
Motor
Page 2